Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2005 |
Principal Product | Fabrication |
NAICS | 331210 - Iron and Steel Pipe and Tube Manufacturing from Purchased Steel |
SIC | 3312 - Blast Furnaces And Steel Mills |
Sales | $50,000,000-$100,000,000 |
# of Employees | 70 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 2,500,000 Pounds |
Production Hrs. Annual | 2,100 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $28,831 | 721,572 | kWh | $0.04 |
Electricity Demand | $25,098 | 2,892 | kW-months/year | $8.68 |
Electricity Fees | $12,122 | - | $ | - |
Natural Gas | $62,682 | 6,502 | MMBtu | $9.64 |
TOTAL ENERGY COSTS | $128,733 | |||
RECOMMENDED SAVINGS* | $73,113 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $63,713 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.426 MODIFY WORKLOAD |
Savings: $42,000 Cost: $3,600 |
- | - | - | - | - | - | - | - | $42,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$42,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $9,925 Cost: $600 |
- | - | - | - | $9,925 | 1,030 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,925 1,030 MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $9,400 Cost: - |
- | - | - | - | - | - | - | - | - | - | $9,400 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
$9,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,192 Cost: $22,500 |
$2,765 | 65,841 | $3,427 | 376 | - | - | - | - | - | - | - | - |
$2,765 65,841 kWh |
$3,427 376 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $4,285 Cost: $300 |
- | - | - | - | - | - | $85 | 1 | $4,200 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$85 1 MMBtu |
$4,200 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $967 Cost: $1,280 |
$348 | 8,272 | $619 | 68 | - | - | - | - | - | - | - | - |
$348 8,272 kWh |
$619 68 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $344 Cost: - |
$153 | 3,654 | $191 | 21 | - | - | - | - | - | - | - | - |
$153 3,654 kWh |
$191 21 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $73,113 Cost: $28,280 |
$3,266 | 77,767 | $4,237 | 465 | $9,925 | 1,030 | $85 | 1 | $46,200 | - | $9,400 | - | $3,266 77,767 kWh |
$4,237 465 kW-months/year |
$9,925 1,030 MMBtu |
$85 1 MMBtu |
$46,200 - $ |
$9,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $63,713 Cost: $28,280 |
$3,266 | 77,767 | $4,237 | 465 | $9,925 | 1,030 | $85 | 1 | $46,200 | - | - | - | $3,266 77,767 kWh |
$4,237 465 kW-months/year |
$9,925 1,030 MMBtu |
$85 1 MMBtu |
$46,200 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Gas | Personnel Changes | Administrative Changes |