Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Wisconsin, Milwaukee |
---|---|
Assessment Year | 2016 |
Principal Product | Cheese, dairy products |
NAICS | 311513 - Cheese Manufacturing |
SIC | 2022 - Cheese, Natural And Processed |
Sales | $100,000,000-$500,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 145,300 |
Annual Production | 70,000 Tons |
Production Hrs. Annual | 8,736 |
Location (State) | WI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,989,463 | 32,237,689 | kWh | $0.06 |
Electricity Demand | $722,604 | 55,702 | kW-months/year | $12.97 |
Electricity Fees | $16,773 | - | $ | - |
Natural Gas | $1,269,679 | 300,031 | MMBtu | $4.23 |
TOTAL ENERGY COSTS | $3,998,519 | |||
RECOMMENDED SAVINGS* | $382,389 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,783 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3112 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS |
Savings: $286,874 Cost: $438,150 |
- | - | $199,896 | 15,408 | $86,978 | - | - | - |
- - kWh |
$199,896 15,408 kW-months/year |
$86,978 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.2176 INCREASE USE OF AUTOMATION |
Savings: $76,440 Cost: $5,500 |
- | - | - | - | - | - | $76,440 | - |
- - kWh |
- - kW-months/year |
- - $ |
$76,440 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $7,438 Cost: $1,560 |
$5,771 | 95,536 | $1,667 | 129 | - | - | - | - |
$5,771 95,536 kWh |
$1,667 129 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,649 Cost: $2,000 |
$3,611 | 58,531 | $1,038 | 80 | - | - | - | - |
$3,611 58,531 kWh |
$1,038 80 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $2,197 Cost: - |
- | - | - | - | $2,197 | - | - | - |
- - kWh |
- - kW-months/year |
$2,197 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,696 Cost: $7,212 |
$2,696 | 43,691 | - | - | - | - | - | - |
$2,696 43,691 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,095 Cost: $735 |
$1,602 | 25,965 | $493 | 38 | - | - | - | - |
$1,602 25,965 kWh |
$493 38 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $382,389 Cost: $455,157 |
$13,680 | 223,723 | $203,094 | 15,655 | $89,175 | - | $76,440 | - | $13,680 223,723 kWh |
$203,094 15,655 kW-months/year |
$89,175 - $ |
$76,440 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,783 Cost: $10,772 |
$12,078 | 197,758 | $2,705 | 209 | - | - | - | - | $12,078 197,758 kWh |
$2,705 209 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes |