IAC logo
IAC Assessment: WM0136
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WM0136
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2019
Principal Product Printed Circuit Board Assemblies
NAICS 334419 - Other Electronic Component Manufacturing
SIC 3679 - Electronic Components, Nec
Sales $10,000,000-$50,000,000
# of Employees 65
Plant Area (Sq.Ft.) 22,280
Annual Production 1,000,000 Pieces
Production Hrs. Annual 5,000
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $69,351 825,600 kWh $0.08
Electricity Demand $14,399 1,986 kW-months/year $7.25
Electricity Fees $(-3,487) - $ -
Natural Gas $4,163 595 MMBtu $7.00
TOTAL ENERGY COSTS $84,426
RECOMMENDED SAVINGS* $32,414 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$23,987
Cost:
$106,000
$23,987 285,565 - - - - $23,987
285,565
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$4,803
Cost:
$4,811
$3,730 44,410 $1,073 148 - - $3,730
44,410
kWh
$1,073
148
kW-months/year
-
-
MMBtu
03: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING Savings:
$1,529
Cost:
$1,319
$1,187 14,135 $341 47 - - $1,187
14,135
kWh
$341
47
kW-months/year
-
-
MMBtu
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$854
Cost:
$1,600
$663 7,896 $191 26 - - $663
7,896
kWh
$191
26
kW-months/year
-
-
MMBtu
05: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$692
Cost:
-
- - - - $692 99 -
-
kWh
-
-
kW-months/year
$692
99
MMBtu
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$549
Cost:
-
$387 4,599 $162 22 - - $387
4,599
kWh
$162
22
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$32,414
Cost:
$113,730
$29,955 356,605 $1,768 244 $692 99 $29,955
356,605
kWh
$1,768
244
kW-months/year
$692
99
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas