Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 1995
Principal Product Vinyl Siding and Window Parts
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $100,000,000-$500,000,000
# of Employees 340
Plant Area (Sq.Ft.) 325,000
Annual Production 100,000,000 Pounds
Production Hrs. Annual 8,736
Location (State) MD
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,309,202 34,197,832 kWh $0.04
TOTAL ENERGY COSTS $1,309,202
RECOMMENDED SAVINGS* $132,143 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $30,681
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$21,730
Cost:
$9,819
$21,730 935,229 $21,730
935,229
kWh
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$17,413
Cost:
$1,130
$17,413 749,414 $17,413
749,414
kWh
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,399
Cost:
$3,964
$1,399 60,082 $1,399
60,082
kWh
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$10,330
Cost:
$30,260
$10,330 241,501 $10,330
241,501
kWh
05: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$34,884
Cost:
$26,775
$34,884 - $34,884
-
kWh
06: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$41,711
Cost:
$1,550
$41,711 1,795,135 $41,711
1,795,135
kWh
07: 2.2511 INSULATE BARE EQUIPMENT Savings:
$890
Cost:
$1,508
$890 38,394 $890
38,394
kWh
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,247
Cost:
$15
$2,247 96,717 $2,247
96,717
kWh
09: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$1,539
Cost:
-
$1,539 66,237 $1,539
66,237
kWh
TOTAL RECOMMENDED Savings:
$132,143
Cost:
$75,021
$132,143 3,982,709 $132,143
3,982,709
kWh
TOTAL IMPLEMENTED Savings:
$30,681
Cost:
$35,354
$30,681 1,117,234 $30,681
1,117,234
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage