Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 1995
Principal Product Blankets
NAICS n/a
SIC 2221 - Broadwoven Fabric Mills, Manmade
Sales $10,000,000-$50,000,000
# of Employees 325
Plant Area (Sq.Ft.) 115,000
Annual Production 3,000,000 Pieces
Production Hrs. Annual 7,344
Location (State) MD
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $241,361 4,811,841 kWh $0.05
Natural Gas $29,050 5,871 MMBtu $4.95
TOTAL ENERGY COSTS $270,411
RECOMMENDED SAVINGS* $18,070 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $16,305
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$176
Cost:
$320
$176 6,741 - - $176
6,741
kWh
-
-
MMBtu
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$6,004
Cost:
$14,890
$6,004 230,363 - - $6,004
230,363
kWh
-
-
MMBtu
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$1,940
Cost:
$1,560
$1,940 74,443 - - $1,940
74,443
kWh
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$271
Cost:
$295
$271 5,862 - - $271
5,862
kWh
-
-
MMBtu
05: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$1,589
Cost:
-
$1,589 60,961 - - $1,589
60,961
kWh
-
-
MMBtu
06: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$1,253
Cost:
$2,300
$1,253 48,066 - - $1,253
48,066
kWh
-
-
MMBtu
07: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE Savings:
$643
Cost:
$1,566
- - $643 130 -
-
kWh
$643
130
MMBtu
08: 2.1123 INSTALL AUTOMATIC STACK DAMPER Savings:
$6,039
Cost:
$560
- - $6,039 1,220 -
-
kWh
$6,039
1,220
MMBtu
09: 2.2511 INSULATE BARE EQUIPMENT Savings:
$155
Cost:
$171
- - $155 31 -
-
kWh
$155
31
MMBtu
TOTAL RECOMMENDED Savings:
$18,070
Cost:
$21,662
$11,233 426,436 $6,837 1,381 $11,233
426,436
kWh
$6,837
1,381
MMBtu
TOTAL IMPLEMENTED Savings:
$16,305
Cost:
$21,342
$9,468 358,734 $6,837 1,381 $9,468
358,734
kWh
$6,837
1,381
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas