Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 1996
Principal Product Valves
NAICS n/a
SIC 3492 - Fluid Power Valves & Hose Fittings
Sales $50,000,000-$100,000,000
# of Employees 240
Plant Area (Sq.Ft.) 70,545
Annual Production 7,000,000 Pieces
Production Hrs. Annual 4,800
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $160,922 4,452,521 kWh $0.04
Electricity Demand $48,022 9,568 kW-months/year $5.02
Electricity Fees $13,563 - $ -
Natural Gas $9,560 2,806 MMBtu $3.41
TOTAL ENERGY COSTS $232,067
RECOMMENDED SAVINGS* $21,509 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,594
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Other Liquid (non-haz) Administrative Changes Electricity Usage Electricity Demand Natural Gas Other Liquid (non-haz) Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ gal $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$7,618
Cost:
$2,400
$5,302 139,215 $2,316 456 - - - - - - $5,302
139,215
kWh
$2,316
456
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$917
Cost:
$6,390
$293 7,620 $624 110 - - - - - - $293
7,620
kWh
$624
110
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$406
Cost:
$1,920
$406 10,551 - - - - - - - - $406
10,551
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,328
Cost:
$748
$1,328 34,877 - - - - - - - - $1,328
34,877
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
05: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$1,774
Cost:
$1,600
$1,774 46,600 - - - - - - - - $1,774
46,600
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
06: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$569
Cost:
$1,467
$569 14,947 - - - - - - - - $569
14,947
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
gal
-
-
$
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$303
Cost:
$523
- - - - $303 89 - - - - -
-
kWh
-
-
kW-months/year
$303
89
MMBtu
-
-
gal
-
-
$
08: 3.1291 ELIMINATE PRACTICE OF MIXING WASTE STREAMS Savings:
$8,594
Cost:
$5,400
$(-251) (-6,448) - - - - $9,085 5,011 $(-240) - $(-251)
(-6,448)
kWh
-
-
kW-months/year
-
-
MMBtu
$9,085
5,011
gal
$(-240)
-
$
TOTAL RECOMMENDED Savings:
$21,509
Cost:
$20,448
$9,421 247,362 $2,940 566 $303 89 $9,085 5,011 $(-240) - $9,421
247,362
kWh
$2,940
566
kW-months/year
$303
89
MMBtu
$9,085
5,011
gal
$(-240)
-
$
TOTAL IMPLEMENTED Savings:
$8,594
Cost:
$5,400
$(-251) (-6,448) - - - - $9,085 5,011 $(-240) - $(-251)
(-6,448)
kWh
-
-
kW-months/year
-
-
MMBtu
$9,085
5,011
gal
$(-240)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ gal $ $
Electricity Usage Electricity Demand Natural Gas Other Liquid (non-haz) Administrative Changes Electricity Usage Electricity Demand Natural Gas Other Liquid (non-haz) Administrative Changes