Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 1996 |
Principal Product | Valves |
NAICS | n/a |
SIC | 3492 - Fluid Power Valves & Hose Fittings |
Sales | $50,000,000-$100,000,000 |
# of Employees | 240 |
Plant Area (Sq.Ft.) | 70,545 |
Annual Production | 7,000,000 Pieces |
Production Hrs. Annual | 4,800 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $160,922 | 4,452,521 | kWh | $0.04 |
Electricity Demand | $48,022 | 9,568 | kW-months/year | $5.02 |
Electricity Fees | $13,563 | - | $ | - |
Natural Gas | $9,560 | 2,806 | MMBtu | $3.41 |
TOTAL ENERGY COSTS | $232,067 | |||
RECOMMENDED SAVINGS* | $21,509 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,594 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,618 Cost: $2,400 |
$5,302 | 139,215 | $2,316 | 456 | - | - | - | - | - | - |
$5,302 139,215 kWh |
$2,316 456 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $917 Cost: $6,390 |
$293 | 7,620 | $624 | 110 | - | - | - | - | - | - |
$293 7,620 kWh |
$624 110 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $406 Cost: $1,920 |
$406 | 10,551 | - | - | - | - | - | - | - | - |
$406 10,551 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,328 Cost: $748 |
$1,328 | 34,877 | - | - | - | - | - | - | - | - |
$1,328 34,877 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,774 Cost: $1,600 |
$1,774 | 46,600 | - | - | - | - | - | - | - | - |
$1,774 46,600 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $569 Cost: $1,467 |
$569 | 14,947 | - | - | - | - | - | - | - | - |
$569 14,947 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $303 Cost: $523 |
- | - | - | - | $303 | 89 | - | - | - | - |
- - kWh |
- - kW-months/year |
$303 89 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.1291 ELIMINATE PRACTICE OF MIXING WASTE STREAMS |
Savings: $8,594 Cost: $5,400 |
$(-251) | (-6,448) | - | - | - | - | $9,085 | 5,011 | $(-240) | - |
$(-251) (-6,448) kWh |
- - kW-months/year |
- - MMBtu |
$9,085 5,011 gal |
$(-240) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $21,509 Cost: $20,448 |
$9,421 | 247,362 | $2,940 | 566 | $303 | 89 | $9,085 | 5,011 | $(-240) | - | $9,421 247,362 kWh |
$2,940 566 kW-months/year |
$303 89 MMBtu |
$9,085 5,011 gal |
$(-240) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,594 Cost: $5,400 |
$(-251) | (-6,448) | - | - | - | - | $9,085 | 5,011 | $(-240) | - | $(-251) (-6,448) kWh |
- - kW-months/year |
- - MMBtu |
$9,085 5,011 gal |
$(-240) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Administrative Changes |