Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 1996 |
Principal Product | Blow Molding Products |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 280 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 125,000 Tons |
Production Hrs. Annual | 8,568 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $487,012 | 19,839,684 | kWh | $0.02 |
Electricity Demand | $272,380 | 35,778 | kW-months/year | $7.61 |
Electricity Fees | $83,584 | - | $ | - |
Natural Gas | $8,641 | 1,383 | MMBtu | $6.25 |
TOTAL ENERGY COSTS | $851,617 | |||
RECOMMENDED SAVINGS* | $270,381 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $257,196 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,489 Cost: $2,245 |
$4,638 | 109,027 | $851 | 156 | - | - | - | - |
$4,638 109,027 kWh |
$851 156 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $4,473 Cost: $6,759 |
$2,430 | 57,151 | $2,043 | 400 | - | - | - | - |
$2,430 57,151 kWh |
$2,043 400 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $6,954 Cost: $1,800 |
$6,954 | 163,834 | - | - | - | - | - | - |
$6,954 163,834 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,197 Cost: $224 |
$3,197 | 75,322 | - | - | - | - | - | - |
$3,197 75,322 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $180 Cost: $520 |
$180 | 4,103 | - | - | - | - | - | - |
$180 4,103 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $240,100 Cost: $11,700 |
$236,223 | 4,431,419 | $3,877 | 775 | - | - | - | - |
$236,223 4,431,419 kWh |
$3,877 775 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $9,988 Cost: $10,000 |
$(-12) | (-293) | - | - | $(-600) | - | $10,600 | - |
$(-12) (-293) kWh |
- - kW-months/year |
$(-600) - $ |
$10,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $270,381 Cost: $33,248 |
$253,610 | 4,840,563 | $6,771 | 1,331 | $(-600) | - | $10,600 | - | $253,610 4,840,563 kWh |
$6,771 1,331 kW-months/year |
$(-600) - $ |
$10,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $257,196 Cost: $23,024 |
$250,425 | 4,765,534 | $6,771 | 1,331 | - | - | - | - | $250,425 4,765,534 kWh |
$6,771 1,331 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes |