Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 1997 |
Principal Product | Mosaic Tiles |
NAICS | n/a |
SIC | 3253 - Ceramic Wall And Floor Tile |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 18,000 Thousand Feet |
Production Hrs. Annual | 6,600 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $47,457 | 2,091,442 | kWh | $0.02 |
Electricity Demand | $81,709 | 4,581 | kW-months/year | $17.84 |
Electricity Fees | $2,668 | - | $ | - |
Natural Gas | $142,583 | 131,467 | MMBtu | $1.08 |
TOTAL ENERGY COSTS | $274,417 | |||
RECOMMENDED SAVINGS* | $428,341 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,018 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Product | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,392 Cost: $309 |
$860 | 35,756 | $1,532 | 86 | - | - | - | - | - | - | - | - |
$860 35,756 kWh |
$1,532 86 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,801 Cost: $1,086 |
$155 | 6,448 | $1,646 | 92 | - | - | - | - | - | - | - | - |
$155 6,448 kWh |
$1,646 92 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $194 Cost: $182 |
$194 | 8,206 | - | - | - | - | - | - | - | - | - | - |
$194 8,206 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $492 Cost: $120 |
$492 | 20,516 | - | - | - | - | - | - | - | - | - | - |
$492 20,516 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $84 Cost: - |
$84 | 3,517 | - | - | - | - | - | - | - | - | - | - |
$84 3,517 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,974 Cost: $214 |
$1,974 | 82,356 | - | - | - | - | - | - | - | - | - | - |
$1,974 82,356 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,275 Cost: $1,788 |
- | - | - | - | $1,275 | 1,180 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,275 1,180 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $369 Cost: $900 |
- | - | - | - | $369 | 342 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$369 342 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $7,280 Cost: $200 |
- | - | - | - | - | - | $2,080 | - | - | - | $5,200 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,080 - $ |
- - $ |
$5,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $12,480 Cost: $200 |
- | - | - | - | - | - | $2,080 | - | - | - | $10,400 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,080 - $ |
- - $ |
$10,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $400,000 Cost: $112,340 |
- | - | - | - | - | - | - | - | $400,000 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$400,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $428,341 Cost: $117,339 |
$3,759 | 156,799 | $3,178 | 178 | $1,644 | 1,522 | $4,160 | - | $400,000 | - | $15,600 | - | $3,759 156,799 kWh |
$3,178 178 kW-months/year |
$1,644 1,522 MMBtu |
$4,160 - $ |
$400,000 - $ |
$15,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,018 Cost: $3,517 |
$3,565 | 148,593 | $3,178 | 178 | $1,275 | 1,180 | - | - | - | - | - | - | $3,565 148,593 kWh |
$3,178 178 kW-months/year |
$1,275 1,180 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Product | By-product Production |