Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 1998
Principal Product Ball Valves
NAICS n/a
SIC 3491 - Industrial Valves
Sales $10,000,000-$50,000,000
# of Employees 80
Plant Area (Sq.Ft.) 30,000
Annual Production 20,000 Pieces
Production Hrs. Annual 2,700
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $50,315 902,403 kWh $0.06
Natural Gas $16,430 2,020 MMBtu $8.13
TOTAL ENERGY COSTS $72,055
RECOMMENDED SAVINGS* $45,415 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,855
#|Description Savings
Cost
Status Electricity Usage Natural Gas Water Disposal Administrative Changes Electricity Usage Natural Gas Water Disposal Administrative Changes
$ kWh $ MMBtu $ Tgal $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$288
Cost:
$87
$288 5,275 - - - - - - $288
5,275
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$346
Cost:
$1,956
$346 6,155 - - - - - - $346
6,155
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$115
Cost:
$128
$115 2,052 - - - - - - $115
2,052
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
04: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$179
Cost:
$336
$179 3,224 - - - - - - $179
3,224
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
05: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$4,542
Cost:
$3,816
$4,542 81,477 - - - - - - $4,542
81,477
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$53
Cost:
$20
$53 879 - - - - - - $53
879
kWh
-
-
MMBtu
-
-
Tgal
-
-
$
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$350
Cost:
$225
- - $350 43 - - - - -
-
kWh
$350
43
MMBtu
-
-
Tgal
-
-
$
08: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION Savings:
$262
Cost:
$620
- - - - $262 42,480 - - -
-
kWh
-
-
MMBtu
$262
42,480
Tgal
-
-
$
09: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER Savings:
$3,780
Cost:
$5,000
- - - - - - $3,780 - -
-
kWh
-
-
MMBtu
-
-
Tgal
$3,780
-
$
10: 4.515 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE Savings:
$35,500
Cost:
-
- - - - - - $35,500 - -
-
kWh
-
-
MMBtu
-
-
Tgal
$35,500
-
$
TOTAL RECOMMENDED Savings:
$45,415
Cost:
$12,188
$5,523 99,062 $350 43 $262 42,480 $39,280 - $5,523
99,062
kWh
$350
43
MMBtu
$262
42,480
Tgal
$39,280
-
$
TOTAL IMPLEMENTED Savings:
$4,855
Cost:
$7,999
$813 14,654 - - $262 42,480 $3,780 - $813
14,654
kWh
-
-
MMBtu
$262
42,480
Tgal
$3,780
-
$
Savings
Cost
$ kWh $ MMBtu $ Tgal $ $
Electricity Usage Natural Gas Water Disposal Administrative Changes Electricity Usage Natural Gas Water Disposal Administrative Changes