Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2002 |
Principal Product | Bricks |
NAICS | n/a |
SIC | 3251 - Brick And Structural Clay Tile |
Sales | $10,000,000-$50,000,000 |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 131,980 |
Annual Production | 55,000,000 Pieces |
Production Hrs. Annual | 4,680 |
Location (State) | MD |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $141,887 | 6,138,639 | kWh | $0.02 |
Electricity Demand | $133,732 | 13,448 | kW-months/year | $9.94 |
Electricity Fees | $40,413 | - | $ | - |
Natural Gas | $1,441,815 | 219,872 | MMBtu | $6.56 |
TOTAL ENERGY COSTS | $1,757,847 | |||
RECOMMENDED SAVINGS* | $29,967 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,894 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,684 Cost: - |
$2,836 | 95,518 | $1,848 | 20 | - | - | - | - | - | - | - | - |
$2,836 95,518 kWh |
$1,848 20 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $348 Cost: $151 |
- | - | - | - | $348 | 53 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$348 53 MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $945 Cost: - |
$573 | 19,227 | $372 | 4 | - | - | - | - | - | - | - | - |
$573 19,227 kWh |
$372 4 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $414 Cost: $100 |
$251 | 8,449 | $163 | 2 | - | - | - | - | - | - | - | - |
$251 8,449 kWh |
$163 2 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6221 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY |
Savings: $6,015 Cost: $230 |
$3,976 | 133,901 | $2,591 | 29 | - | - | - | - | $(-552) | - | - | - |
$3,976 133,901 kWh |
$2,591 29 kW-months/year |
- - MMBtu |
- - lb |
$(-552) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,109 Cost: $138 |
$1,131 | 50,689 | $978 | 11 | - | - | - | - | - | - | - | - |
$1,131 50,689 kWh |
$978 11 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,052 Cost: $930 |
$635 | 21,389 | $417 | 5 | - | - | - | - | - | - | - | - |
$635 21,389 kWh |
$417 5 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $579 Cost: $300 |
$191 | 6,446 | $388 | 4 | - | - | - | - | - | - | - | - |
$191 6,446 kWh |
$388 4 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $5,021 Cost: $4,000 |
- | - | - | - | - | - | $5,021 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,021 - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $3,800 Cost: $690 |
- | - | - | - | - | - | - | - | - | - | $3,800 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$3,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $5,000 Cost: $845 |
- | - | - | - | - | - | - | - | - | - | $5,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
$5,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $29,967 Cost: $7,384 |
$9,593 | 335,619 | $6,757 | 75 | $348 | 53 | $5,021 | - | $(-552) | - | $8,800 | - | $9,593 335,619 kWh |
$6,757 75 kW-months/year |
$348 53 MMBtu |
$5,021 - lb |
$(-552) - $ |
$8,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,894 Cost: $1,609 |
$8,958 | 314,230 | $6,340 | 70 | $348 | 53 | - | - | $(-552) | - | $3,800 | - | $8,958 314,230 kWh |
$6,340 70 kW-months/year |
$348 53 MMBtu |
- - lb |
$(-552) - $ |
$3,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||