Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2006 |
Principal Product | Industrial Storage Bins |
NAICS | 337215 - Showcase, Partition, Shelving, and Locker Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 190,000 |
Annual Production | 24,500,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $899,353 | 13,300,200 | kWh | $0.07 |
Electricity Demand | $200,721 | 22,768 | kW-months/year | $8.82 |
Electricity Fees | $1,689 | - | $ | - |
Natural Gas | $106,204 | 10,148 | MMBtu | $10.47 |
TOTAL ENERGY COSTS | $1,207,967 | |||
RECOMMENDED SAVINGS* | $120,653 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $70,261 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $50,392 Cost: $80,000 |
- | - | - | - | - | - | $50,392 | 4,813 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$50,392 4,813 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $21,971 Cost: $13,343 |
$17,146 | 327,210 | $4,825 | 547 | - | - | - | - | - | - |
$17,146 327,210 kWh |
$4,825 547 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $20,449 Cost: $12,020 |
- | - | - | - | $20,449 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$20,449 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $11,461 Cost: $648 |
$9,916 | 189,278 | $2,385 | 270 | - | - | - | - | $(-840) | - |
$9,916 189,278 kWh |
$2,385 270 kW-months/year |
- - $ |
- - MMBtu |
$(-840) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $5,398 Cost: $350 |
- | - | $5,398 | 612 | - | - | - | - | - | - |
- - kWh |
$5,398 612 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7314 REDUCE VENTILATION AIR |
Savings: $3,560 Cost: $892 |
$768 | 14,650 | $185 | 21 | - | - | $2,607 | 249 | - | - |
$768 14,650 kWh |
$185 21 kW-months/year |
- - $ |
$2,607 249 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,103 Cost: $473 |
$2,103 | 40,141 | - | - | - | - | - | - | - | - |
$2,103 40,141 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,543 Cost: $650 |
$829 | 15,739 | $714 | 81 | - | - | - | - | - | - |
$829 15,739 kWh |
$714 81 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $1,275 Cost: $2,748 |
$1,028 | 19,631 | $247 | 28 | - | - | - | - | - | - |
$1,028 19,631 kWh |
$247 28 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,226 Cost: - |
$744 | 14,209 | $482 | 55 | - | - | - | - | - | - |
$744 14,209 kWh |
$482 55 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $874 Cost: $145 |
$706 | 13,444 | $168 | 19 | - | - | - | - | - | - |
$706 13,444 kWh |
$168 19 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $401 Cost: $170 |
$322 | 6,153 | $79 | 9 | - | - | - | - | - | - |
$322 6,153 kWh |
$79 9 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $120,653 Cost: $111,439 |
$33,562 | 640,455 | $14,483 | 1,642 | $20,449 | - | $52,999 | 5,062 | $(-840) | - | $33,562 640,455 kWh |
$14,483 1,642 kW-months/year |
$20,449 - $ |
$52,999 5,062 MMBtu |
$(-840) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $70,261 Cost: $31,439 |
$33,562 | 640,455 | $14,483 | 1,642 | $20,449 | - | $2,607 | 249 | $(-840) | - | $33,562 640,455 kWh |
$14,483 1,642 kW-months/year |
$20,449 - $ |
$2,607 249 MMBtu |
$(-840) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Personnel Changes |