Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2009 |
Principal Product | Chromatography Columns and Accessories |
NAICS | 334513 - Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
SIC | 3826 - Analytical Instruments |
Sales | $50,000,000-$100,000,000 |
# of Employees | 270 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 640,000 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $227,041 | 4,433,633 | kWh | $0.05 |
Electricity Demand | $42,207 | 9,417 | kW-months/year | $4.48 |
Natural Gas | $75,820 | 6,108 | MMBtu | $12.41 |
TOTAL ENERGY COSTS | $345,068 | |||
RECOMMENDED SAVINGS* | $39,875 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,593 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $5,844 Cost: $1,000 |
$5,187 | 101,282 | $873 | 195 | - | - | $(-216) | - |
$5,187 101,282 kWh |
$873 195 kW-months/year |
- - MMBtu |
$(-216) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,876 Cost: $5,376 |
$4,173 | 81,489 | $703 | 157 | - | - | - | - |
$4,173 81,489 kWh |
$703 157 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $4,832 Cost: $4,053 |
$4,111 | 80,282 | $721 | 161 | - | - | - | - |
$4,111 80,282 kWh |
$721 161 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $4,703 Cost: $662 |
$4,149 | 81,025 | $698 | 156 | - | - | $(-144) | - |
$4,149 81,025 kWh |
$698 156 kW-months/year |
- - MMBtu |
$(-144) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $4,461 Cost: $1,740 |
$1,321 | 25,805 | $224 | 50 | $2,916 | 235 | - | - |
$1,321 25,805 kWh |
$224 50 kW-months/year |
$2,916 235 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $3,065 Cost: $8,080 |
- | - | - | - | $3,065 | 247 | - | - |
- - kWh |
- - kW-months/year |
$3,065 247 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $2,517 Cost: $960 |
$2,056 | 40,141 | $461 | 103 | - | - | - | - |
$2,056 40,141 kWh |
$461 103 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,947 Cost: $290 |
$1,665 | 32,522 | $282 | 63 | - | - | - | - |
$1,665 32,522 kWh |
$282 63 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,740 Cost: $600 |
- | - | - | - | $1,812 | 146 | $(-72) | - |
- - kWh |
- - kW-months/year |
$1,812 146 MMBtu |
$(-72) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR |
Savings: $1,613 Cost: $6,810 |
- | - | - | - | $1,613 | 130 | - | - |
- - kWh |
- - kW-months/year |
$1,613 130 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,462 Cost: $2,860 |
$1,251 | 24,436 | $211 | 47 | - | - | - | - |
$1,251 24,436 kWh |
$211 47 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,327 Cost: - |
$1,134 | 22,137 | $193 | 43 | - | - | - | - |
$1,134 22,137 kWh |
$193 43 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $962 Cost: - |
$823 | 16,074 | $139 | 31 | - | - | - | - |
$823 16,074 kWh |
$139 31 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $526 Cost: - |
- | - | $1,102 | 246 | - | - | $(-576) | - |
- - kWh |
$1,102 246 kW-months/year |
- - MMBtu |
$(-576) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $39,875 Cost: $32,431 |
$25,870 | 505,193 | $5,607 | 1,252 | $9,406 | 758 | $(-1,008) | - | $25,870 505,193 kWh |
$5,607 1,252 kW-months/year |
$9,406 758 MMBtu |
$(-1,008) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,593 Cost: $6,082 |
$13,777 | 269,021 | $2,436 | 544 | $1,812 | 146 | $(-432) | - | $13,777 269,021 kWh |
$2,436 544 kW-months/year |
$1,812 146 MMBtu |
$(-432) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |