Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2010 |
Principal Product | Window Balance Systems |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 75 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 20,000,000 Pieces |
Production Hrs. Annual | 4,080 |
Location (State) | MD |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $156,442 | 1,748,670 | kWh | $0.09 |
Electricity Demand | $16,974 | 6,346 | kW-months/year | $2.67 |
Electricity Fees | $988 | - | $ | - |
LPG | $28,289 | 1,130 | MMBtu | $25.03 |
TOTAL ENERGY COSTS | $202,693 | |||
RECOMMENDED SAVINGS* | $28,772 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $25,083 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Electricity Usage | Electricity Demand | LPG | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,129 Cost: $42,755 |
$9,312 | 104,089 | $817 | 306 | - | - |
$9,312 104,089 kWh |
$817 306 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $8,114 Cost: $4,540 |
- | - | - | - | $8,114 | 326 |
- - kWh |
- - kW-months/year |
$8,114 326 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,475 Cost: $4,751 |
$2,253 | 25,189 | $222 | 83 | - | - |
$2,253 25,189 kWh |
$222 83 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7314 REDUCE VENTILATION AIR |
Savings: $1,892 Cost: $1,078 |
- | - | - | - | $1,892 | 76 |
- - kWh |
- - kW-months/year |
$1,892 76 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $1,917 Cost: $804 |
$1,768 | 19,762 | $149 | 58 | - | - |
$1,768 19,762 kWh |
$149 58 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,359 Cost: $588 |
$1,250 | 13,970 | $109 | 41 | - | - |
$1,250 13,970 kWh |
$109 41 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $1,180 Cost: $10,000 |
$1,038 | 11,601 | $142 | 53 | - | - |
$1,038 11,601 kWh |
$142 53 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM |
Savings: $747 Cost: $1,000 |
- | - | - | - | $747 | 30 |
- - kWh |
- - kW-months/year |
$747 30 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $398 Cost: $342 |
$366 | 4,089 | $32 | 12 | - | - |
$366 4,089 kWh |
$32 12 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $367 Cost: $27 |
$338 | 3,780 | $29 | 11 | - | - |
$338 3,780 kWh |
$29 11 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES |
Savings: $194 Cost: - |
$194 | 1,990 | - | - | - | - |
$194 1,990 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $28,772 Cost: $65,885 |
$16,519 | 184,470 | $1,500 | 564 | $10,753 | 432 | $16,519 184,470 kWh |
$1,500 564 kW-months/year |
$10,753 432 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $25,083 Cost: $54,739 |
$13,153 | 147,028 | $1,177 | 441 | $10,753 | 432 | $13,153 147,028 kWh |
$1,177 441 kW-months/year |
$10,753 432 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Electricity Usage | Electricity Demand | LPG |