Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2014 |
Principal Product | rigid plastic film |
NAICS | 326113 - Unlaminated Plastics Film and Sheet (except Packaging) Manufacturing |
SIC | 3081 - Unsupported Plastics Film & Sheet |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 75,000 |
Annual Production | 46,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $585,867 | 14,577,300 | kWh | $0.04 |
Electricity Demand | $377,115 | 28,880 | kW-months/year | $13.06 |
Natural Gas | $44,131 | 5,776 | MMBtu | $7.64 |
TOTAL ENERGY COSTS | $1,007,113 | |||
RECOMMENDED SAVINGS* | $60,283 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,424 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $19,697 Cost: $36,851 |
$13,650 | 337,699 | $6,047 | 463 | - | - | - | - |
$13,650 337,699 kWh |
$6,047 463 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $14,611 Cost: $72,000 |
$10,131 | 250,633 | $4,480 | 343 | - | - | - | - |
$10,131 250,633 kWh |
$4,480 343 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $10,571 Cost: $1,000 |
$8,209 | 203,089 | $3,631 | 278 | - | - | $(-1,269) | - |
$8,209 203,089 kWh |
$3,631 278 kW-months/year |
- - MMBtu |
$(-1,269) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $5,404 Cost: - |
- | - | $6,028 | 612 | - | - | $(-624) | - |
- - kWh |
$6,028 612 kW-months/year |
- - MMBtu |
$(-624) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $3,317 Cost: $381 |
$2,519 | 62,311 | $1,110 | 85 | - | - | $(-312) | - |
$2,519 62,311 kWh |
$1,110 85 kW-months/year |
- - MMBtu |
$(-312) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,285 Cost: $4,251 |
- | - | - | - | $3,285 | 430 | - | - |
- - kWh |
- - kW-months/year |
$3,285 430 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,147 Cost: $2,480 |
- | - | - | - | $2,147 | 281 | - | - |
- - kWh |
- - kW-months/year |
$2,147 281 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $794 Cost: $1,293 |
$546 | 13,500 | $248 | 19 | - | - | - | - |
$546 13,500 kWh |
$248 19 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $457 Cost: $13 |
$313 | 7,754 | $144 | 11 | - | - | - | - |
$313 7,754 kWh |
$144 11 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $60,283 Cost: $118,269 |
$35,368 | 874,986 | $21,688 | 1,811 | $5,432 | 711 | $(-2,205) | - | $35,368 874,986 kWh |
$21,688 1,811 kW-months/year |
$5,432 711 MMBtu |
$(-2,205) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,424 Cost: $6,938 |
$11,587 | 286,654 | $5,133 | 393 | $3,285 | 430 | $(-1,581) | - | $11,587 286,654 kWh |
$5,133 393 kW-months/year |
$3,285 430 MMBtu |
$(-1,581) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |