IAC logo
IAC Assessment: WV0552
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WV0552
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2017
Principal Product Water
NAICS 221310 - Water Supply and Irrigation Systems
SIC 4941 - Water Supply
Sales $50,000,000-$100,000,000
# of Employees 17
Plant Area (Sq.Ft.) 476,685
Annual Production 11,000,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) PA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,874,718 31,217,030 kWh $0.06
Electricity Demand $69,796 65,712 kW-months/year $1.06
Natural Gas $42,910 5,816 MMBtu $7.38
TOTAL ENERGY COSTS $1,987,424
RECOMMENDED SAVINGS* $169,073 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $32,860
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$108,472
Cost:
$401,920
$108,472 1,804,860 - - - - - - - - $108,472
1,804,860
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
02: 2.3137 USE POWER DURING OFF-PEAK PERIODS Savings:
$17,322
Cost:
$2,500
- - $3,562 3,360 - - $(-6,240) - $20,000 - -
-
kWh
$3,562
3,360
kW-months/year
-
-
MMBtu
$(-6,240)
-
$
$20,000
-
$
03: 2.7264 INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION Savings:
$14,015
Cost:
$46,500
$12,065 200,745 $983 927 $967 131 - - - - $12,065
200,745
kWh
$983
927
kW-months/year
$967
131
MMBtu
-
-
$
-
-
$
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$13,726
Cost:
$620
$13,714 228,180 $332 313 - - - - $(-320) - $13,714
228,180
kWh
$332
313
kW-months/year
-
-
MMBtu
-
-
$
$(-320)
-
$
05: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM Savings:
$9,424
Cost:
$1,000
$10,158 169,023 $246 232 - - - - $(-980) - $10,158
169,023
kWh
$246
232
kW-months/year
-
-
MMBtu
-
-
$
$(-980)
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,201
Cost:
$10,486
$3,106 51,688 $95 90 - - - - - - $3,106
51,688
kWh
$95
90
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,913
Cost:
$3,240
$2,844 47,329 $69 65 - - - - - - $2,844
47,329
kWh
$69
65
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$169,073
Cost:
$466,266
$150,359 2,501,825 $5,287 4,987 $967 131 $(-6,240) - $18,700 - $150,359
2,501,825
kWh
$5,287
4,987
kW-months/year
$967
131
MMBtu
$(-6,240)
-
$
$18,700
-
$
TOTAL IMPLEMENTED Savings:
$32,860
Cost:
$17,226
$16,108 268,040 $3,972 3,747 - - $(-6,240) - $19,020 - $16,108
268,040
kWh
$3,972
3,747
kW-months/year
-
-
MMBtu
$(-6,240)
-
$
$19,020
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes