Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2017 |
Principal Product | Water |
NAICS | 221310 - Water Supply and Irrigation Systems |
SIC | 4941 - Water Supply |
Sales | $50,000,000-$100,000,000 |
# of Employees | 17 |
Plant Area (Sq.Ft.) | 476,685 |
Annual Production | 11,000,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,874,718 | 31,217,030 | kWh | $0.06 |
Electricity Demand | $69,796 | 65,712 | kW-months/year | $1.06 |
Natural Gas | $42,910 | 5,816 | MMBtu | $7.38 |
TOTAL ENERGY COSTS | $1,987,424 | |||
RECOMMENDED SAVINGS* | $169,073 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $32,860 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $108,472 Cost: $401,920 |
$108,472 | 1,804,860 | - | - | - | - | - | - | - | - |
$108,472 1,804,860 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3137 USE POWER DURING OFF-PEAK PERIODS |
Savings: $17,322 Cost: $2,500 |
- | - | $3,562 | 3,360 | - | - | $(-6,240) | - | $20,000 | - |
- - kWh |
$3,562 3,360 kW-months/year |
- - MMBtu |
$(-6,240) - $ |
$20,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7264 INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION |
Savings: $14,015 Cost: $46,500 |
$12,065 | 200,745 | $983 | 927 | $967 | 131 | - | - | - | - |
$12,065 200,745 kWh |
$983 927 kW-months/year |
$967 131 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $13,726 Cost: $620 |
$13,714 | 228,180 | $332 | 313 | - | - | - | - | $(-320) | - |
$13,714 228,180 kWh |
$332 313 kW-months/year |
- - MMBtu |
- - $ |
$(-320) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $9,424 Cost: $1,000 |
$10,158 | 169,023 | $246 | 232 | - | - | - | - | $(-980) | - |
$10,158 169,023 kWh |
$246 232 kW-months/year |
- - MMBtu |
- - $ |
$(-980) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,201 Cost: $10,486 |
$3,106 | 51,688 | $95 | 90 | - | - | - | - | - | - |
$3,106 51,688 kWh |
$95 90 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,913 Cost: $3,240 |
$2,844 | 47,329 | $69 | 65 | - | - | - | - | - | - |
$2,844 47,329 kWh |
$69 65 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $169,073 Cost: $466,266 |
$150,359 | 2,501,825 | $5,287 | 4,987 | $967 | 131 | $(-6,240) | - | $18,700 | - | $150,359 2,501,825 kWh |
$5,287 4,987 kW-months/year |
$967 131 MMBtu |
$(-6,240) - $ |
$18,700 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $32,860 Cost: $17,226 |
$16,108 | 268,040 | $3,972 | 3,747 | - | - | $(-6,240) | - | $19,020 | - | $16,108 268,040 kWh |
$3,972 3,747 kW-months/year |
- - MMBtu |
$(-6,240) - $ |
$19,020 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes |