Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2018 |
Principal Product | Waste Water Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $10,000,000-$50,000,000 |
# of Employees | 8 |
Plant Area (Sq.Ft.) | 280,000 |
Annual Production | 2,555,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $108,040 | 1,032,620 | kWh | $0.10 |
Electricity Demand | $15,183 | 3,322 | kW-months/year | $4.57 |
Electricity Fees | $432 | - | $ | - |
Fuel Oil #2 | $10,240 | 569 | MMBtu | $18.00 |
TOTAL ENERGY COSTS | $133,895 | |||
RECOMMENDED SAVINGS* | $47,084 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,409 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $15,162 Cost: $53,700 |
$14,307 | 136,782 | $855 | 187 | - | - | - | - | - | - |
$14,307 136,782 kWh |
$855 187 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1332 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS |
Savings: $10,502 Cost: $18,000 |
- | - | - | - | $(-2,738) | (-547) | $10,240 | 569 | $3,000 | - |
- - kWh |
- - kW-months/year |
$(-2,738) (-547) MMBtu |
$10,240 569 MMBtu |
$3,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4313 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT |
Savings: $6,339 Cost: $6,000 |
$5,983 | 57,196 | $356 | 78 | - | - | - | - | - | - |
$5,983 57,196 kWh |
$356 78 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1336 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL |
Savings: $5,001 Cost: $25,000 |
- | - | - | - | - | - | $5,001 | 278 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,001 278 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7264 INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION |
Savings: $2,502 Cost: $7,080 |
$1,999 | 19,109 | $503 | 110 | - | - | - | - | - | - |
$1,999 19,109 kWh |
$503 110 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $2,455 Cost: $1,000 |
$3,623 | 34,632 | $215 | 47 | - | - | - | - | $(-1,383) | - |
$3,623 34,632 kWh |
$215 47 kW-months/year |
- - MMBtu |
- - MMBtu |
$(-1,383) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $2,327 Cost: $4,400 |
$2,194 | 20,971 | $133 | 29 | - | - | - | - | - | - |
$2,194 20,971 kWh |
$133 29 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,289 Cost: $3,732 |
$2,120 | 20,269 | $169 | 37 | - | - | - | - | - | - |
$2,120 20,269 kWh |
$169 37 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $507 Cost: $638 |
$666 | 6,366 | $41 | 9 | - | - | - | - | $(-200) | - |
$666 6,366 kWh |
$41 9 kW-months/year |
- - MMBtu |
- - MMBtu |
$(-200) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $47,084 Cost: $119,550 |
$30,892 | 295,325 | $2,272 | 497 | $(-2,738) | (-547) | $15,241 | 847 | $1,417 | - | $30,892 295,325 kWh |
$2,272 497 kW-months/year |
$(-2,738) (-547) MMBtu |
$15,241 847 MMBtu |
$1,417 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,409 Cost: $101,432 |
$20,050 | 191,683 | $1,239 | 271 | $(-2,738) | (-547) | $15,241 | 847 | $1,617 | - | $20,050 191,683 kWh |
$1,239 271 kW-months/year |
$(-2,738) (-547) MMBtu |
$15,241 847 MMBtu |
$1,617 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Personnel Changes |