Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2022
Principal Product Gas Production Unit
NAICS 237120 - Oil and Gas Pipeline and Related Structures Construction
SIC 1623 - Water, Sewer, And Utility Lines
Sales $10,000,000-$50,000,000
# of Employees 75
Plant Area (Sq.Ft.) 120,000
Annual Production 1,000 Units
Production Hrs. Annual 2,500
Location (State) WV
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $56,161 1,267,745 kWh $0.04
Electricity Demand $81,311 4,922 kW-months/year $16.52
Electricity Fees $1,630 - $ -
Natural Gas $88,615 10,477 MMBtu $8.46
TOTAL ENERGY COSTS $229,887
RECOMMENDED SAVINGS* $59,719 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,827
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Usage Water Disposal Personnel Changes Electricity Usage Electricity Demand Water Usage Water Disposal Personnel Changes
$ kWh $ kW-months/year $ Tgal $ Tgal $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$15,156
Cost:
$10,857
$5,426 122,486 $9,730 589 - - - - - - $5,426
122,486
kWh
$9,730
589
kW-months/year
-
-
Tgal
-
-
Tgal
-
-
$
02: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS Savings:
$13,877
Cost:
$5,625
- - $13,877 840 - - - - - - -
-
kWh
$13,877
840
kW-months/year
-
-
Tgal
-
-
Tgal
-
-
$
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$7,979
Cost:
$36,800
$2,858 64,512 $5,121 310 - - - - - - $2,858
64,512
kWh
$5,121
310
kW-months/year
-
-
Tgal
-
-
Tgal
-
-
$
04: 3.4151 MINIMIZE WATER USAGE Savings:
$7,539
Cost:
$4,229
$(-25) (-566) - - $7,087 120 $961 120 $(-484) - $(-25)
(-566)
kWh
-
-
kW-months/year
$7,087
120
Tgal
$961
120
Tgal
$(-484)
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,341
Cost:
$12,560
$1,781 40,209 $4,560 276 - - - - - - $1,781
40,209
kWh
$4,560
276
kW-months/year
-
-
Tgal
-
-
Tgal
-
-
$
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$5,499
Cost:
$3,930
$1,534 34,627 $3,965 240 - - - - - - $1,534
34,627
kWh
$3,965
240
kW-months/year
-
-
Tgal
-
-
Tgal
-
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,727
Cost:
$145
$620 14,006 $1,107 67 - - - - - - $620
14,006
kWh
$1,107
67
kW-months/year
-
-
Tgal
-
-
Tgal
-
-
$
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,085
Cost:
$50
$391 8,817 $694 42 - - - - - - $391
8,817
kWh
$694
42
kW-months/year
-
-
Tgal
-
-
Tgal
-
-
$
09: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$516
Cost:
$552
$186 4,203 $330 20 - - - - - - $186
4,203
kWh
$330
20
kW-months/year
-
-
Tgal
-
-
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$59,719
Cost:
$74,748
$12,771 288,294 $39,384 2,384 $7,087 120 $961 120 $(-484) - $12,771
288,294
kWh
$39,384
2,384
kW-months/year
$7,087
120
Tgal
$961
120
Tgal
$(-484)
-
$
TOTAL IMPLEMENTED Savings:
$8,827
Cost:
$4,677
$2,731 61,653 $6,096 369 - - - - - - $2,731
61,653
kWh
$6,096
369
kW-months/year
-
-
Tgal
-
-
Tgal
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ Tgal $ Tgal $ $
Electricity Usage Electricity Demand Water Usage Water Disposal Personnel Changes Electricity Usage Electricity Demand Water Usage Water Disposal Personnel Changes