Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2023 |
Principal Product | Green Hardwood Lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $5,000,000-$10,000,000 |
# of Employees | 28 |
Plant Area (Sq.Ft.) | 15,957 |
Annual Production | 15,957 Units |
Production Hrs. Annual | 2,250 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $49,514 | 879,496 | kWh | $0.06 |
Electricity Demand | $63,522 | 4,307 | kW-months/year | $14.75 |
Electricity Fees | $10,594 | - | $ | - |
TOTAL ENERGY COSTS | $123,630 | |||
RECOMMENDED SAVINGS* | $33,272 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,744 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $15,045 Cost: $75,000 |
- | - | $15,045 | 1,020 | - | - | - | - |
- - kWh |
$15,045 1,020 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $5,278 Cost: $7,699 |
- | - | - | - | $5,278 | - | - | - |
- - kWh |
- - kW-months/year |
$5,278 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $2,796 Cost: $1,931 |
$1,218 | 21,634 | $1,578 | 107 | - | - | - | - |
$1,218 21,634 kWh |
$1,578 107 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,218 Cost: $3,090 |
$920 | 16,335 | $1,298 | 88 | - | - | - | - |
$920 16,335 kWh |
$1,298 88 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,542 Cost: $7,652 |
$642 | 11,406 | $900 | 61 | - | - | - | - |
$642 11,406 kWh |
$900 61 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,494 Cost: $566 |
$624 | 11,075 | $870 | 59 | - | - | - | - |
$624 11,075 kWh |
$870 59 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $1,285 Cost: $1,500 |
$821 | 14,582 | $1,151 | 78 | - | - | $(-687) | - |
$821 14,582 kWh |
$1,151 78 kW-months/year |
- - $ |
$(-687) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $1,085 Cost: $1,500 |
$739 | 13,124 | $1,033 | 70 | - | - | $(-687) | - |
$739 13,124 kWh |
$1,033 70 kW-months/year |
- - $ |
$(-687) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $997 Cost: $3,526 |
$416 | 7,383 | $581 | 39 | - | - | - | - |
$416 7,383 kWh |
$581 39 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $798 Cost: $127 |
$798 | 14,171 | - | - | - | - | - | - |
$798 14,171 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $611 Cost: $1,094 |
$277 | 4,921 | $384 | 26 | - | - | $(-50) | - |
$277 4,921 kWh |
$384 26 kW-months/year |
- - $ |
$(-50) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $123 Cost: $219 |
$49 | 878 | $74 | 5 | - | - | - | - |
$49 878 kWh |
$74 5 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,272 Cost: $103,904 |
$6,504 | 115,509 | $22,914 | 1,553 | $5,278 | - | $(-1,424) | - | $6,504 115,509 kWh |
$22,914 1,553 kW-months/year |
$5,278 - $ |
$(-1,424) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,744 Cost: $18,053 |
$4,211 | 74,783 | $5,907 | 400 | - | - | $(-1,374) | - | $4,211 74,783 kWh |
$5,907 400 kW-months/year |
- - $ |
$(-1,374) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes |