Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
63
matching recommendationsNAICS | 2213 | Water, Sewage and Other Systems |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1075 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $168 | $855 | Implemented |
OK1075 # 01 Y:2022 | 01 | 2022 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,542 | $3,232 | Not Implemented |
OK1058 # 04 Y:2021 | 04 | 2021 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $185 | $700 | Implemented |
OK1058 # 03 Y:2021 | 03 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,252 | $7,778 | Implemented |
OK1058 # 02 Y:2021 | 02 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $455 | $2,130 | Not Implemented |
OK1058 # 01 Y:2021 | 01 | 2021 | OPTIMIZE PLANT POWER FACTOR | $1,800 | $3,000 | Not Implemented |
OK1056 # 01 Y:2021 | 01 | 2021 | RECOVER AND REUSE WASTE MATERIAL | $10,400 | $0 | Not Implemented |
OK1056 # 04 Y:2021 | 04 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46 | $162 | Implemented |
OK1056 # 03 Y:2021 | 03 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $425 | $629 | Implemented |
OK1056 # 02 Y:2021 | 02 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,775 | $3,987 | Not Implemented |
OK1038 # 01 Y:2021 | 01 | 2021 | INSTALL OCCUPANCY SENSORS | $563 | $1,944 | Not Implemented |
OK1038 # 02 Y:2021 | 02 | 2021 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $24,443 | $2,171 | Not Implemented |
OK1038 # 03 Y:2021 | 03 | 2021 | INSTALL TIMERS AND/OR THERMOSTATS | $991 | $0 | Not Implemented |
OK1036 # 04 Y:2020 | 04 | 2020 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $209 | $1,390 | Implemented |
OK1036 # 05 Y:2020 | 05 | 2020 | INSTALL TIMERS AND/OR THERMOSTATS | $283 | $312 | Implemented |
OK1036 # 03 Y:2020 | 03 | 2020 | USE RADIANT HEATER FOR SPOT HEATING | $1,151 | $3,500 | Not Implemented |
OK1036 # 02 Y:2020 | 02 | 2020 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $43,157 | $12,222 | Not Implemented |
OK1036 # 01 Y:2020 | 01 | 2020 | INSTALL OCCUPANCY SENSORS | $450 | $1,163 | Implemented |
OK1030 # 04 Y:2020 | 04 | 2020 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $80,268 | $2,200 | Not Implemented |
OK1030 # 03 Y:2020 | 03 | 2020 | INSTALL OCCUPANCY SENSORS | $629 | $387 | Not Implemented |
OK1030 # 02 Y:2020 | 02 | 2020 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,018 | $7,359 | Not Implemented |
OK1030 # 01 Y:2020 | 01 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,533 | $4,129 | Not Implemented |
OK1027 # 05 Y:2020 | 05 | 2020 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $48,801 | $12,552 | Not Implemented |
OK1027 # 04 Y:2020 | 04 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,521 | $4,542 | Implemented |
OK1027 # 03 Y:2020 | 03 | 2020 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,207 | $7,407 | Not Implemented |