Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
1,632
matching recommendationsNAICS | 221320 | Sewage Treatment Facilities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0536 # 06 Y:2016 | 06 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $1,406 | $617 | Implemented |
WV0536 # 07 Y:2016 | 07 | 2016 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $735 | $4,320 | Implemented |
WV0536 # 08 Y:2016 | 08 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $394 | $60 | Not Implemented |
UK1608 # 01 Y:2016 | 01 | 2016 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $125,405 | $660,000 | Not Implemented |
UK1608 # 02 Y:2016 | 02 | 2016 | UPGRADE OBSOLETE EQUIPMENT | $15,087 | $75,544 | Implemented |
UK1608 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,569 | $9,415 | Not Implemented |
MA0764 # 01 Y:2016 | 01 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $45,693 | $125,000 | Not Implemented |
MA0764 # 02 Y:2016 | 02 | 2016 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $3,889 | $5,000 | Not Implemented |
MA0764 # 03 Y:2016 | 03 | 2016 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,264 | $500 | Not Implemented |
UK1607 # 01 Y:2016 | 01 | 2016 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $53,387 | $292,000 | Not Implemented |
UK1607 # 02 Y:2016 | 02 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,600 | $41,160 | Implemented |
UK1607 # 03 Y:2016 | 03 | 2016 | UPGRADE OBSOLETE EQUIPMENT | $19,747 | $4,240 | Implemented |
UK1607 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $469 | $1,775 | Implemented |
UK1606 # 01 Y:2016 | 01 | 2016 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $19,749 | $90,000 | Not Implemented |
UK1606 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,258 | $7,310 | Not Implemented |
UK1606 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,300 | $8,440 | Not Implemented |
UK1606 # 04 Y:2016 | 04 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $316 | $0 | Not Implemented |
UK1606 # 05 Y:2016 | 05 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,013 | $0 | Not Implemented |
UK1606 # 06 Y:2016 | 06 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,016 | $2,500 | Not Implemented |
SU0419 # 01 Y:2016 | 01 | 2016 | INSTALL TIMERS AND/OR THERMOSTATS | $506 | $412 | Not Implemented |
SU0419 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $246 | $190 | Not Implemented |
SU0419 # 03 Y:2016 | 03 | 2016 | USE PHOTOCELL CONTROLS | $477 | $451 | Not Implemented |
SU0419 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,749 | $7,697 | Not Implemented |
SU0419 # 05 Y:2016 | 05 | 2016 | REDUCE VENTILATION AIR | $491 | $899 | Not Implemented |
DL0165 # 01 Y:2016 | 01 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,622 | $1,000 | Implemented |