Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,562
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0709 # 03 Y:2015 | 03 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $840 | $1,110 | Not Implemented |
CO0709 # 04 Y:2015 | 04 | 2015 | AVOID FROST FORMATION ON EVAPORATORS | $380 | $1,960 | Not Implemented |
CO0709 # 05 Y:2015 | 05 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $260 | $590 | Not Implemented |
CO0709 # 06 Y:2015 | 06 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,560 | $500 | Implemented |
CO0709 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,300 | $10,780 | Implemented |
CO0709 # 08 Y:2015 | 08 | 2015 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $1,160 | $8,080 | Not Implemented |
MZ0185 # 01 Y:2015 | 01 | 2015 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $444,193 | $2,686,745 | Not Implemented |
MZ0185 # 02 Y:2015 | 02 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $4,593 | $7,228 | Implemented |
MZ0185 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $16,223 | $0 | Not Implemented |
MZ0185 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,296 | $9,730 | Implemented |
MZ0185 # 05 Y:2015 | 05 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $92,880 | $450,000 | Not Implemented |
MZ0185 # 06 Y:2015 | 06 | 2015 | USE PHOTOCELL CONTROLS | $30,214 | $15,000 | Implemented |
TT0160 # 01 Y:2015 | 01 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $112,350 | $2,000 | Not Implemented |
TT0160 # 02 Y:2015 | 02 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $25,461 | $298 | Implemented |
TT0160 # 03 Y:2015 | 03 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $13,910 | $100 | Not Implemented |
TT0160 # 04 Y:2015 | 04 | 2015 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $10,534 | $21,195 | Implemented |
TT0160 # 05 Y:2015 | 05 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,397 | $10,000 | Not Implemented |
TT0160 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $8,554 | $14,129 | Not Implemented |
TT0160 # 07 Y:2015 | 07 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,882 | $0 | Not Implemented |
TT0160 # 08 Y:2015 | 08 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,322 | $0 | Not Implemented |
TT0160 # 09 Y:2015 | 09 | 2015 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,335 | $2,000 | Not Implemented |
TT0160 # 10 Y:2015 | 10 | 2015 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $527 | $1,176 | Not Implemented |
MA0747 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $115,415 | $139,825 | Not Implemented |
MA0747 # 02 Y:2015 | 02 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $77,983 | $96,200 | Not Implemented |
MA0747 # 03 Y:2015 | 03 | 2015 | OPTIMIZE PLANT POWER FACTOR | $28,243 | $56,115 | Not Implemented |