Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9,562

matching recommendations
Reset
NAICS 311 Food Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0709 # 03 Y:2015 03 2015 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $840 $1,110 Not Implemented
CO0709 # 04 Y:2015 04 2015 AVOID FROST FORMATION ON EVAPORATORS $380 $1,960 Not Implemented
CO0709 # 05 Y:2015 05 2015 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $260 $590 Not Implemented
CO0709 # 06 Y:2015 06 2015 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,560 $500 Implemented
CO0709 # 07 Y:2015 07 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,300 $10,780 Implemented
CO0709 # 08 Y:2015 08 2015 USE SOLAR HEAT TO HEAT MAKE-UP AIR $1,160 $8,080 Not Implemented
MZ0185 # 01 Y:2015 01 2015 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $444,193 $2,686,745 Not Implemented
MZ0185 # 02 Y:2015 02 2015 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $4,593 $7,228 Implemented
MZ0185 # 03 Y:2015 03 2015 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $16,223 $0 Not Implemented
MZ0185 # 04 Y:2015 04 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,296 $9,730 Implemented
MZ0185 # 05 Y:2015 05 2015 UTILIZE A LESS EXPENSIVE COOLING METHOD $92,880 $450,000 Not Implemented
MZ0185 # 06 Y:2015 06 2015 USE PHOTOCELL CONTROLS $30,214 $15,000 Implemented
TT0160 # 01 Y:2015 01 2015 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $112,350 $2,000 Not Implemented
TT0160 # 02 Y:2015 02 2015 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $25,461 $298 Implemented
TT0160 # 03 Y:2015 03 2015 REPAIR AND ELIMINATE STEAM LEAKS $13,910 $100 Not Implemented
TT0160 # 04 Y:2015 04 2015 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $10,534 $21,195 Implemented
TT0160 # 05 Y:2015 05 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,397 $10,000 Not Implemented
TT0160 # 06 Y:2015 06 2015 INSTALL OCCUPANCY SENSORS $8,554 $14,129 Not Implemented
TT0160 # 07 Y:2015 07 2015 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $4,882 $0 Not Implemented
TT0160 # 08 Y:2015 08 2015 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,322 $0 Not Implemented
TT0160 # 09 Y:2015 09 2015 INCREASE AMOUNT OF CONDENSATE RETURNED $1,335 $2,000 Not Implemented
TT0160 # 10 Y:2015 10 2015 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $527 $1,176 Not Implemented
MA0747 # 01 Y:2015 01 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $115,415 $139,825 Not Implemented
MA0747 # 02 Y:2015 02 2015 RECOVER WASTE HEAT FROM EQUIPMENT $77,983 $96,200 Not Implemented
MA0747 # 03 Y:2015 03 2015 OPTIMIZE PLANT POWER FACTOR $28,243 $56,115 Not Implemented