Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,562
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0507 # 11 Y:2006 | 11 | 2006 | USE PHOTOCELL CONTROLS | $1,120 | $100 | Implemented |
AM0507 # 12 Y:2006 | 12 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $938 | $215 | Implemented |
UU0101 # 01 Y:2006 | 01 | 2006 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $16,190 | $10,000 | Not Implemented |
UU0101 # 02 Y:2006 | 02 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,280 | $4,150 | Not Implemented |
UU0101 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,230 | $3,050 | Not Implemented |
UU0101 # 04 Y:2006 | 04 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,760 | $10,030 | Not Implemented |
UU0101 # 05 Y:2006 | 05 | 2006 | OPTIMIZE PLANT POWER FACTOR | $3,770 | $4,140 | Not Implemented |
UU0101 # 06 Y:2006 | 06 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $100,330 | $52,800 | Not Implemented |
OK0726 # 01 Y:2006 | 01 | 2006 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,838 | $2,305 | Not Implemented |
OK0726 # 02 Y:2006 | 02 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $11,412 | $13,554 | Not Implemented |
OK0726 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $2,127 | $339 | Not Implemented |
OK0726 # 04 Y:2006 | 04 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $21,283 | $32,000 | Not Implemented |
OK0726 # 05 Y:2006 | 05 | 2006 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $18,769 | $16,500 | Not Implemented |
OK0726 # 06 Y:2006 | 06 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $31,992 | $32,500 | Not Implemented |
OK0726 # 07 Y:2006 | 07 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $55,348 | $35,269 | Not Implemented |
OK0726 # 08 Y:2006 | 08 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,168 | $8,723 | Not Implemented |
OK0726 # 09 Y:2006 | 09 | 2006 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $579 | $2,006 | Not Implemented |
OK0726 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $1,213 | $331 | Not Implemented |
OK0726 # 11 Y:2006 | 11 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,188 | $5,750 | Not Implemented |
OK0725 # 01 Y:2006 | 01 | 2006 | OPTIMIZE PLANT POWER FACTOR | $36,035 | $14,223 | Not Implemented |
OK0725 # 02 Y:2006 | 02 | 2006 | INSULATE BARE EQUIPMENT | $1,143 | $339 | Not Implemented |
OK0725 # 03 Y:2006 | 03 | 2006 | INSTALL OCCUPANCY SENSORS | $365 | $437 | Not Implemented |
OK0725 # 04 Y:2006 | 04 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $29,580 | $24,609 | Not Implemented |
OK0725 # 05 Y:2006 | 05 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,367 | $27,265 | Not Implemented |
LM0113 # 01 Y:2006 | 01 | 2006 | CONDENSE OPERATION INTO ONE BUILDING | $333,734 | $180,000 | Not Implemented |