Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
183
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0226 # 03 Y:2017 | 03 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,988 | $1,115 | Implemented |
MZ0226 # 02 Y:2017 | 02 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,166 | $0 | Not Implemented |
MZ0226 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,015 | $5,450 | Implemented |
MZ0216 # 05 Y:2016 | 05 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $2,001 | $2,000 | Implemented |
MZ0216 # 04 Y:2016 | 04 | 2016 | INSTALL OCCUPANCY SENSORS | $389 | $280 | Not Implemented |
MZ0216 # 03 Y:2016 | 03 | 2016 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $404 | $800 | Implemented |
MZ0216 # 02 Y:2016 | 02 | 2016 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,373 | $12,000 | Implemented |
MZ0216 # 01 Y:2016 | 01 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $859 | $1,000 | Not Implemented |
MZ0215 # 04 Y:2016 | 04 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $567 | $0 | Not Implemented |
MZ0215 # 03 Y:2016 | 03 | 2016 | INSTALL OCCUPANCY SENSORS | $1,093 | $220 | Implemented |
MZ0215 # 02 Y:2016 | 02 | 2016 | INSULATE BARE EQUIPMENT | $2,514 | $1,500 | Implemented |
MZ0215 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,397 | $8,400 | Implemented |
MZ0185 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $16,223 | $0 | Not Implemented |
MZ0185 # 01 Y:2015 | 01 | 2015 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $444,193 | $2,686,745 | Not Implemented |
MZ0185 # 02 Y:2015 | 02 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $4,593 | $7,228 | Implemented |
MZ0185 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,296 | $9,730 | Implemented |
MZ0185 # 05 Y:2015 | 05 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $92,880 | $450,000 | Not Implemented |
MZ0185 # 06 Y:2015 | 06 | 2015 | USE PHOTOCELL CONTROLS | $30,214 | $15,000 | Implemented |
MZ0182 # 03 Y:2015 | 03 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,623 | $0 | Not Implemented |
MZ0182 # 01 Y:2015 | 01 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,344 | $5,600 | Not Implemented |
MZ0182 # 02 Y:2015 | 02 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $9,859 | $1,100 | Not Implemented |
MZ0182 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $1,985 | $1,740 | Not Implemented |
MZ0182 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,921 | $15,600 | Not Implemented |
MZ0182 # 06 Y:2015 | 06 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $37,902 | $42,400 | Not Implemented |
MZ0176 # 03 Y:2015 | 03 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $16,004 | $6,500 | Not Implemented |