Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,562
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0811 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,607 | $6,694 | Not Implemented |
GT0811 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $14,135 | $3,000 | Implemented |
GT0811 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,312 | $750 | Implemented |
GT0811 # 06 Y:2005 | 06 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,877 | $1,300 | Implemented |
GT0811 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,119 | $5,334 | Not Implemented |
GT0811 # 08 Y:2005 | 08 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $162,720 | $25,000 | Not Implemented |
IC0110 # 01 Y:2005 | 01 | 2005 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $106,617 | $213,420 | Implemented |
IC0110 # 02 Y:2005 | 02 | 2005 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $79,621 | $634,572 | Not Implemented |
IC0110 # 03 Y:2005 | 03 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $29,831 | $1,638 | Implemented |
IC0110 # 04 Y:2005 | 04 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $6,051 | $400 | Implemented |
IC0110 # 05 Y:2005 | 05 | 2005 | IMPROVE COMBUSTION CONTROL CAPABILITY | $13,789 | $3,500 | Implemented |
IC0110 # 06 Y:2005 | 06 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,956 | $0 | Implemented |
IC0110 # 07 Y:2005 | 07 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $7,443 | $15,000 | Not Implemented |
IC0110 # 08 Y:2005 | 08 | 2005 | OPTIMIZE PLANT POWER FACTOR | $13,904 | $70,000 | Implemented |
IC0110 # 09 Y:2005 | 09 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,156 | $81,881 | Implemented |
IC0110 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $473 | $3,388 | Implemented |
SD0373 # 01 Y:2005 | 01 | 2005 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $34,083 | $56,520 | Not Implemented |
SD0373 # 02 Y:2005 | 02 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,494 | $3,900 | Not Implemented |
SD0373 # 03 Y:2005 | 03 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,208 | $0 | Not Implemented |
SD0373 # 04 Y:2005 | 04 | 2005 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,475 | $450 | Not Implemented |
SD0373 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,918 | $36,052 | Not Implemented |
SD0373 # 06 Y:2005 | 06 | 2005 | USE PHOTOCELL CONTROLS | $4,982 | $615 | Not Implemented |
SD0373 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $3,212 | $90 | Not Implemented |
SD0373 # 08 Y:2005 | 08 | 2005 | INSTALL AUTOMATIC PACKING EQUIPMENT | $171,742 | $50,000 | Not Implemented |
SD0373 # 09 Y:2005 | 09 | 2005 | AUTOMATE FINISHING PROCESS | $17,209 | $30,000 | Not Implemented |