Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,562
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0330 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,173 | $7,342 | Implemented |
IA0330 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $866 | $1,149 | Implemented |
IA0330 # 09 Y:2003 | 09 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,303 | $0 | Implemented |
IA0330 # 10 Y:2003 | 10 | 2003 | INSTALL OCCUPANCY SENSORS | $684 | $1,064 | Implemented |
OR0442 # 01 Y:2003 | 01 | 2003 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $27,900 | $23,290 | Not Implemented |
OR0442 # 02 Y:2003 | 02 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $21,500 | $11,700 | Implemented |
OR0442 # 03 Y:2003 | 03 | 2003 | USE PHOTOCELL CONTROLS | $11,250 | $1,340 | Not Implemented |
OR0442 # 04 Y:2003 | 04 | 2003 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $7,900 | $0 | Implemented |
OR0442 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,470 | $0 | Implemented |
OR0442 # 06 Y:2003 | 06 | 2003 | INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE | $580 | $1,400 | Not Implemented |
OR0441 # 01 Y:2003 | 01 | 2003 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $65,260 | $70,100 | Implemented |
OR0441 # 02 Y:2003 | 02 | 2003 | SHUT OFF STEAM TRAPS ON SUPER HEATED STEAM LINES WHEN NOT IN USE | $18,970 | $2,160 | Implemented |
OR0441 # 03 Y:2003 | 03 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,670 | $985 | Implemented |
OR0441 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,900 | $10,080 | Implemented |
OR0440 # 01 Y:2003 | 01 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $1,842,800 | $348,000 | Implemented |
OR0440 # 02 Y:2003 | 02 | 2003 | MOVE PRODUCT USING MECHANICAL MEANS | $15,000 | $75 | Not Implemented |
OR0440 # 03 Y:2003 | 03 | 2003 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $16,500 | $5,130 | Implemented |
OR0440 # 04 Y:2003 | 04 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,500 | $0 | Not Implemented |
OR0440 # 05 Y:2003 | 05 | 2003 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $2,600 | $700 | Implemented |
OR0440 # 06 Y:2003 | 06 | 2003 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $765 | $1,300 | Not Implemented |
OR0440 # 07 Y:2003 | 07 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $15,500 | $38,200 | Implemented |
OR0439 # 01 Y:2003 | 01 | 2003 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $330,000 | $790,000 | Implemented |
OR0439 # 02 Y:2003 | 02 | 2003 | INCREASE AMOUNT OF CONDENSATE RETURNED | $13,400 | $28,000 | Not Implemented |
OR0439 # 03 Y:2003 | 03 | 2003 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,500 | $450 | Implemented |
OR0439 # 04 Y:2003 | 04 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,500 | $1,850 | Implemented |