Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
207
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0566 # 03 Y:2016 | 03 | 2016 | INSTALL OCCUPANCY SENSORS | $3,889 | $5,100 | Implemented |
IA0566 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,660 | $6,945 | Implemented |
IA0566 # 05 Y:2016 | 05 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,966 | $195 | Implemented |
IA0566 # 06 Y:2016 | 06 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,284 | $1,000 | Implemented |
IA0566 # 07 Y:2016 | 07 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $592 | $70 | Implemented |
WM0095 # 01 Y:2016 | 01 | 2016 | STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS | $286,874 | $438,150 | Not Implemented |
WM0095 # 02 Y:2016 | 02 | 2016 | INCREASE USE OF AUTOMATION | $76,440 | $5,500 | Not Implemented |
WM0095 # 03 Y:2016 | 03 | 2016 | REPAIR AND ELIMINATE STEAM LEAKS | $7,438 | $1,560 | Implemented |
WM0095 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,649 | $2,000 | Implemented |
WM0095 # 06 Y:2016 | 06 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,696 | $7,212 | Implemented |
WM0095 # 07 Y:2016 | 07 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,095 | $735 | Not Implemented |
WM0095 # 05 Y:2016 | 05 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,197 | $0 | Not Implemented |
WM0092 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $824 | $2,005 | Not Implemented |
WM0092 # 04 Y:2016 | 04 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,104 | $375 | Implemented |
WM0092 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,511 | $3,000 | Not Implemented |
WM0092 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,120 | $1,420 | Implemented |
WM0092 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,839 | $5,000 | Implemented |
WM0089 # 06 Y:2016 | 06 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $392 | $690 | Not Implemented |
WM0089 # 01 Y:2016 | 01 | 2016 | INSTALL OCCUPANCY SENSORS | $15,954 | $6,213 | Not Implemented |
WM0089 # 02 Y:2016 | 02 | 2016 | USE PHOTOCELL CONTROLS | $628 | $290 | Not Implemented |
WM0089 # 03 Y:2016 | 03 | 2016 | INCREASE USE OF AUTOMATION | $52,696 | $6,000 | Not Implemented |
WM0089 # 05 Y:2016 | 05 | 2016 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $11,093 | $0 | Not Implemented |
WM0089 # 04 Y:2016 | 04 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,394 | $0 | Not Implemented |
WM0070 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $2,580 | $570 | Implemented |
WM0070 # 04 Y:2015 | 04 | 2015 | USE RADIANT HEATER FOR SPOT HEATING | $4,545 | $6,320 | Not Implemented |