Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
120
matching recommendationsNAICS | 311 | Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0340 # 02 Y:2004 | 02 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,101 | $1,000 | Implemented |
IA0340 # 03 Y:2004 | 03 | 2004 | CONTROL PRESSURE ON STEAMER OPERATIONS | $18,750 | $4,940 | Implemented |
IA0340 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $343 | $263 | Not Implemented |
IA0340 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $686 | $962 | Implemented |
IA0340 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,946 | $135 | Implemented |
IA0340 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,093 | $4,412 | Not Implemented |
IA0340 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $787 | $1,397 | Not Implemented |
IA0340 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,397 | $1,494 | Not Implemented |
IA0340 # 10 Y:2004 | 10 | 2004 | USE SCREENING, MAGNETIC SEPARATION TO REMOVE CONTAMINANTS | $12,424 | $12,000 | Not Implemented |
IA0340 # 11 Y:2004 | 11 | 2004 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $16,000 | $36,000 | Implemented |
IA0330 # 01 Y:2003 | 01 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,889 | $1,000 | Not Implemented |
IA0330 # 02 Y:2003 | 02 | 2003 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $916 | $1,734 | Not Implemented |
IA0330 # 03 Y:2003 | 03 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $34,175 | $36,000 | Not Implemented |
IA0330 # 04 Y:2003 | 04 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $487 | $23 | Implemented |
IA0330 # 05 Y:2003 | 05 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,233 | $220 | Implemented |
IA0330 # 06 Y:2003 | 06 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,040 | $99 | Implemented |
IA0330 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,173 | $7,342 | Implemented |
IA0330 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $866 | $1,149 | Implemented |
IA0330 # 09 Y:2003 | 09 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,303 | $0 | Implemented |
IA0330 # 10 Y:2003 | 10 | 2003 | INSTALL OCCUPANCY SENSORS | $684 | $1,064 | Implemented |