Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
246
matching recommendationsNAICS | 3111 | Animal Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0720 # 06 Y:2005 | 06 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,280 | $540 | Implemented |
UD0720 # 10 Y:2005 | 10 | 2005 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $1,072 | $2,000 | Implemented |
UD0720 # 11 Y:2005 | 11 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $554 | $0 | Implemented |
UD0720 # 13 Y:2005 | 13 | 2005 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $390 | $0 | Implemented |
UD0720 # 15 Y:2005 | 15 | 2005 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $200 | $340 | Implemented |
AM0472 # 01 Y:2004 | 01 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $6,580 | $590 | Implemented |
AM0472 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $6,640 | $720 | Implemented |
AM0472 # 04 Y:2004 | 04 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $950 | $290 | Implemented |
AM0472 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,000 | $200 | Implemented |
AM0472 # 06 Y:2004 | 06 | 2004 | INSTALL SKYLIGHTS | $920 | $0 | Implemented |
AM0471 # 01 Y:2004 | 01 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $7,600 | $930 | Implemented |
AM0471 # 02 Y:2004 | 02 | 2004 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $6,640 | $4,600 | Implemented |
AM0471 # 03 Y:2004 | 03 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,020 | $270 | Implemented |
AM0471 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,450 | $400 | Implemented |
AM0471 # 05 Y:2004 | 05 | 2004 | USE SYNTHETIC LUBRICANT | $1,920 | $0 | Implemented |
AM0471 # 06 Y:2004 | 06 | 2004 | INSULATE BARE EQUIPMENT | $1,110 | $170 | Implemented |
AM0471 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $230 | $630 | Implemented |
CO0545 # 01 Y:2004 | 01 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $8,950 | $1,500 | Implemented |
CO0545 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $5,800 | $1,760 | Implemented |
CO0545 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $355 | $800 | Implemented |
CO0545 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,170 | $420 | Implemented |
IA0340 # 02 Y:2004 | 02 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,101 | $1,000 | Implemented |
IA0340 # 03 Y:2004 | 03 | 2004 | CONTROL PRESSURE ON STEAMER OPERATIONS | $18,750 | $4,940 | Implemented |
IA0340 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $686 | $962 | Implemented |
IA0340 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,946 | $135 | Implemented |