Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
537
matching recommendationsNAICS | 31111 | Animal Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0720 # 05 Y:2005 | 05 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,200 | $225 | Implemented |
UD0720 # 06 Y:2005 | 06 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,280 | $540 | Implemented |
UD0720 # 07 Y:2005 | 07 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,655 | $0 | Not Implemented |
UD0720 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,333 | $5,120 | Not Implemented |
UD0720 # 09 Y:2005 | 09 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,103 | $400 | Not Implemented |
UD0720 # 10 Y:2005 | 10 | 2005 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $1,072 | $2,000 | Implemented |
UD0720 # 11 Y:2005 | 11 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $554 | $0 | Implemented |
UD0720 # 12 Y:2005 | 12 | 2005 | INSULATE BARE EQUIPMENT | $483 | $379 | Not Implemented |
UD0720 # 13 Y:2005 | 13 | 2005 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $390 | $0 | Implemented |
UD0720 # 14 Y:2005 | 14 | 2005 | USE PHOTOCELL CONTROLS | $296 | $500 | Not Implemented |
UD0720 # 15 Y:2005 | 15 | 2005 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $200 | $340 | Implemented |
UU0076 # 01 Y:2004 | 01 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,600 | $2,000 | Not Implemented |
UU0076 # 02 Y:2004 | 02 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $24 | $40 | Not Implemented |
UU0076 # 03 Y:2004 | 03 | 2004 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $30 | $0 | Not Implemented |
UU0076 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,300 | $4,824 | Not Implemented |
UU0076 # 05 Y:2004 | 05 | 2004 | METER WASTE WATER | $5,360 | $1,500 | Not Implemented |
UU0076 # 06 Y:2004 | 06 | 2004 | OPTIMIZE PLANT POWER FACTOR | $1,982 | $2,220 | Not Implemented |
AM0472 # 01 Y:2004 | 01 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $6,580 | $590 | Implemented |
AM0472 # 02 Y:2004 | 02 | 2004 | INSULATE BARE EQUIPMENT | $6,640 | $720 | Implemented |
AM0472 # 03 Y:2004 | 03 | 2004 | USE SYNTHETIC LUBRICANT | $2,630 | $0 | Not Implemented |
AM0472 # 04 Y:2004 | 04 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $950 | $290 | Implemented |
AM0472 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,000 | $200 | Implemented |
AM0472 # 06 Y:2004 | 06 | 2004 | INSTALL SKYLIGHTS | $920 | $0 | Implemented |
AM0471 # 01 Y:2004 | 01 | 2004 | REPAIR OR REPLACE STEAM TRAPS | $7,600 | $930 | Implemented |
AM0471 # 02 Y:2004 | 02 | 2004 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $6,640 | $4,600 | Implemented |