Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
34
matching recommendationsNAICS | 3112 | Grain and Oilseed Milling |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0589 # 04 Y:2006 | 04 | 2006 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $23,960 | $0 | Implemented |
CO0589 # 02 Y:2006 | 02 | 2006 | USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER | $56,580 | $570 | Implemented |
CO0589 # 01 Y:2006 | 01 | 2006 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $264,540 | $1,173,000 | Not Implemented |
CO0589 # 05 Y:2006 | 05 | 2006 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $21,540 | $100,800 | Not Implemented |
CO0589 # 03 Y:2006 | 03 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $950 | $500 | Implemented |
CO0589 # 06 Y:2006 | 06 | 2006 | USE SOLAR HEAT TO MAKE ELECTRICTY | $3,910 | $32,600 | Not Implemented |
WI0521 # 05 Y:2006 | 05 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,630 | $3,200 | Not Implemented |
WI0521 # 04 Y:2006 | 04 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,386 | $11,000 | Not Implemented |
WI0521 # 03 Y:2006 | 03 | 2006 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $6,900 | $18,000 | Not Implemented |
WI0521 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,408 | $13,600 | Not Implemented |
WI0521 # 01 Y:2006 | 01 | 2006 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $222,888 | $230,600 | Not Implemented |
WI0521 # 06 Y:2006 | 06 | 2006 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,035 | $500 | Not Implemented |
WI0521 # 07 Y:2006 | 07 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $630 | $0 | Not Implemented |
LL0247 # 05 Y:2006 | 05 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $333 | $60 | Implemented |
LL0247 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $210 | $120 | Implemented |
LL0247 # 04 Y:2006 | 04 | 2006 | USE PHOTOCELL CONTROLS | $527 | $150 | Not Implemented |
LL0247 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $570 | $151 | Implemented |
LL0247 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,136 | $1,373 | Not Implemented |
LL0247 # 01 Y:2006 | 01 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,342 | $2,748 | Not Implemented |
LL0248 # 01 Y:2006 | 01 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,816 | $14,656 | Not Implemented |
LL0248 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,463 | $1,022 | Implemented |
LL0248 # 03 Y:2006 | 03 | 2006 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,218 | $80 | Implemented |
LL0248 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $959 | $151 | Implemented |
LL0248 # 06 Y:2006 | 06 | 2006 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $900 | $300 | Implemented |
LL0248 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $619 | $150 | Not Implemented |