Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsNAICS | 31131 | Sugar Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0462 # 01 Y:2013 | 01 | 2013 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $298,848 | $180,000 | Not Implemented |
WV0462 # 07 Y:2013 | 07 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $25,992 | $29,385 | Implemented |
WV0462 # 08 Y:2013 | 08 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,934 | $15,779 | Implemented |
WV0462 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,970 | $1,530 | Implemented |
WV0462 # 10 Y:2013 | 10 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $7,809 | $8,200 | Implemented |
WV0462 # 11 Y:2013 | 11 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,390 | $7,119 | Implemented |
WV0462 # 12 Y:2013 | 12 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $476 | $604 | Not Implemented |
LL0269 # 13 Y:2007 | 13 | 2007 | INSULATE BARE EQUIPMENT | $34 | $442 | Implemented |
LL0269 # 07 Y:2007 | 07 | 2007 | USE PHOTOCELL CONTROLS | $3,736 | $270 | Implemented |
LL0269 # 06 Y:2007 | 06 | 2007 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $6,878 | $164 | Implemented |
LL0269 # 05 Y:2007 | 05 | 2007 | OPTIMIZE PLANT POWER FACTOR | $8,830 | $4,603 | Not Implemented |
LL0269 # 04 Y:2007 | 04 | 2007 | INCREASE AMOUNT OF CONDENSATE RETURNED | $22,967 | $178,238 | Not Implemented |
LL0269 # 03 Y:2007 | 03 | 2007 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $31,500 | $21,500 | Not Implemented |
LL0269 # 02 Y:2007 | 02 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $60,227 | $12,430 | Implemented |
LL0269 # 01 Y:2007 | 01 | 2007 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $573,938 | $2,150,000 | Implemented |
LL0269 # 08 Y:2007 | 08 | 2007 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,485 | $195 | Implemented |
LL0269 # 09 Y:2007 | 09 | 2007 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $1,192 | $720 | Implemented |
LL0269 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $763 | $546 | Not Implemented |
LL0269 # 11 Y:2007 | 11 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $694 | $623 | Not Implemented |
LL0269 # 12 Y:2007 | 12 | 2007 | PAY BILLS ON TIME TO AVOID LATE FEES | $118 | $0 | Not Implemented |
SD0368 # 11 Y:2005 | 11 | 2005 | INSTALL EQUIPMENT TO MOVE PRODUCT | $80,484 | $5,965 | Not Implemented |
SD0368 # 10 Y:2005 | 10 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $15,102 | $20,000 | Not Implemented |
SD0368 # 09 Y:2005 | 09 | 2005 | MAKE A NEW BY-PRODUCT | $194,263 | $172,000 | Not Implemented |
SD0368 # 08 Y:2005 | 08 | 2005 | SELL / OFFER BY-PRODUCT AS ANIMAL FEED | $539,275 | $68,000 | Not Implemented |
SD0368 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,660 | $13,282 | Not Implemented |