Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

84

matching recommendations
Reset
NAICS 311314 Cane Sugar Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0462 # 02 Y:2013 02 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $167,190 $95,000 Not Implemented
WV0462 # 01 Y:2013 01 2013 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $298,848 $180,000 Not Implemented
WV0462 # 12 Y:2013 12 2013 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $476 $604 Not Implemented
LL0269 # 12 Y:2007 12 2007 $118 $0 Not Implemented
LL0269 # 01 Y:2007 01 2007 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $573,938 $2,150,000 Implemented
LL0269 # 02 Y:2007 02 2007 REPAIR AND ELIMINATE STEAM LEAKS $60,227 $12,430 Implemented
LL0269 # 03 Y:2007 03 2007 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $31,500 $21,500 Not Implemented
LL0269 # 04 Y:2007 04 2007 INCREASE AMOUNT OF CONDENSATE RETURNED $22,967 $178,238 Not Implemented
LL0269 # 05 Y:2007 05 2007 OPTIMIZE PLANT POWER FACTOR $8,830 $4,603 Not Implemented
LL0269 # 06 Y:2007 06 2007 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $6,878 $164 Implemented
LL0269 # 07 Y:2007 07 2007 USE PHOTOCELL CONTROLS $3,736 $270 Implemented
LL0269 # 08 Y:2007 08 2007 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,485 $195 Implemented
LL0269 # 09 Y:2007 09 2007 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT $1,192 $720 Implemented
LL0269 # 10 Y:2007 10 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $763 $546 Not Implemented
LL0269 # 11 Y:2007 11 2007 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $694 $623 Not Implemented
LL0269 # 13 Y:2007 13 2007 INSULATE BARE EQUIPMENT $34 $442 Implemented
SD0368 # 10 Y:2005 10 2005 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $15,102 $20,000 Not Implemented
SD0368 # 01 Y:2005 01 2005 REPAIR AND ELIMINATE STEAM LEAKS $85,079 $99,260 Not Implemented
SD0368 # 02 Y:2005 02 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $82,308 $130,000 Not Implemented
SD0368 # 03 Y:2005 03 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $49,689 $30,500 Not Implemented
SD0368 # 04 Y:2005 04 2005 REPAIR OR REPLACE STEAM TRAPS $41,386 $11,940 Not Implemented
SD0368 # 05 Y:2005 05 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $39,379 $59,781 Not Implemented
SD0368 # 06 Y:2005 06 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $5,259 $4,056 Not Implemented
SD0368 # 07 Y:2005 07 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,660 $13,282 Not Implemented
SD0368 # 08 Y:2005 08 2005 SELL / OFFER BY-PRODUCT AS ANIMAL FEED $539,275 $68,000 Not Implemented