Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
132
matching recommendationsNAICS | 311352 | Confectionery Manufacturing from Purchased Chocolate |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0233 # 06 Y:2006 | 06 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,416 | $2,500 | Not Implemented |
LE0233 # 07 Y:2006 | 07 | 2006 | INSULATE BARE EQUIPMENT | $881 | $197 | Not Implemented |
LE0233 # 08 Y:2006 | 08 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $789 | $1,000 | Not Implemented |
LE0233 # 09 Y:2006 | 09 | 2006 | INSTALL OCCUPANCY SENSORS | $465 | $375 | Not Implemented |
LE0233 # 10 Y:2006 | 10 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,514 | $12,000 | Implemented |
LL0204 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,973 | $20,331 | Implemented |
LL0204 # 02 Y:2004 | 02 | 2004 | INSTALL OCCUPANCY SENSORS | $6,514 | $360 | Implemented |
LL0204 # 03 Y:2004 | 03 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $6,025 | $3,880 | Implemented |
LL0204 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,085 | $680 | Implemented |
LL0204 # 05 Y:2004 | 05 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,710 | $1,350 | Implemented |
LL0204 # 06 Y:2004 | 06 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $2,273 | $45 | Implemented |
LL0204 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,897 | $30 | Implemented |
LL0204 # 08 Y:2004 | 08 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,728 | $90 | Not Implemented |
LL0204 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,123 | $1,400 | Not Implemented |
LL0204 # 10 Y:2004 | 10 | 2004 | USE PHOTOCELL CONTROLS | $278 | $28 | Not Implemented |
LL0204 # 11 Y:2004 | 11 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $106,500 | $5,180 | Implemented |
LL0204 # 12 Y:2004 | 12 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $11,190 | $6,417 | Implemented |
SU0173 # 01 Y:2004 | 01 | 2004 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $13,244 | $0 | Not Implemented |
SU0173 # 02 Y:2004 | 02 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,991 | $0 | Not Implemented |
SU0173 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $919 | $57 | Implemented |
SU0173 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,102 | $117 | Not Implemented |
SU0173 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,444 | $4,290 | Not Implemented |
SU0173 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,001 | $9,164 | Implemented |
SU0173 # 07 Y:2004 | 07 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,555 | $48,418 | Not Implemented |
IA0315 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,493 | $910 | Implemented |