IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,566

matching recommendations
Reset
NAICS 3114 Fruit and Vegetable Preserving and Specialty Food Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0257 # 09 Y:2014 09 2014 INSTALL OCCUPANCY SENSORS $2,579 $290 Implemented
OR0626 # 01 Y:2014 01 2014 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $18,202 $6,792 Not Implemented
OR0626 # 02 Y:2014 02 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,945 $1,000 Not Implemented
OR0626 # 03 Y:2014 03 2014 IMPROVE COMBUSTION CONTROL CAPABILITY $11,422 $7,219 Not Implemented
OR0626 # 04 Y:2014 04 2014 UPGRADE CONTROLS ON COMPRESSORS $7,138 $5,500 Not Implemented
OR0626 # 05 Y:2014 05 2014 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $5,445 $6,461 Not Implemented
OR0626 # 06 Y:2014 06 2014 INSULATE BARE EQUIPMENT $3,138 $5,659 Not Implemented
OR0626 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,463 $3,437 Not Implemented
BD0440 # 01 Y:2014 01 2014 INCREASE AMOUNT OF CONDENSATE RETURNED $54,036 $150,000 Not Implemented
BD0440 # 02 Y:2014 02 2014 REPLACE BOILER $35,950 $170,000 Not Implemented
BD0440 # 03 Y:2014 03 2014 USE RADIANT HEATER FOR SPOT HEATING $17,194 $15,200 Not Implemented
BD0440 # 04 Y:2014 04 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $6,523 $6,400 Not Implemented
BD0440 # 05 Y:2014 05 2014 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,300 $22,220 Not Implemented
BD0440 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,816 $3,025 Not Implemented
BD0440 # 07 Y:2014 07 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,177 $20 Not Implemented
BD0440 # 08 Y:2014 08 2014 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,947 $4,500 Not Implemented
BD0440 # 09 Y:2014 09 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,645 $4,750 Not Implemented
BD0440 # 10 Y:2014 10 2014 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $570 $40 Not Implemented
BD0440 # 11 Y:2014 11 2014 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $11,389 $8,000 Not Implemented
MZ0132 # 01 Y:2013 01 2013 OPERATE BOILERS ON HIGH FIRE SETTING $67,232 $111,000 Not Implemented
MZ0132 # 02 Y:2013 02 2013 INCREASE AMOUNT OF CONDENSATE RETURNED $28,581 $40,000 Implemented
MZ0132 # 03 Y:2013 03 2013 RECOVER WASTE HEAT FROM EQUIPMENT $28,256 $4,000 Not Implemented
MZ0132 # 04 Y:2013 04 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,620 $3,100 Not Implemented
MZ0132 # 05 Y:2013 05 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,108 $1,630 Implemented
MZ0132 # 06 Y:2013 06 2013 RECOVER WASTE HEAT FROM EQUIPMENT $5,895 $2,000 Not Implemented