Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsNAICS | 3114 | Fruit and Vegetable Preserving and Specialty Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0238 # 07 Y:2024 | 07 | 2024 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $212,600 | $900,000 | n/a |
DL0238 # 06 Y:2024 | 06 | 2024 | REPAIR AND ELIMINATE STEAM LEAKS | $56,437 | $22,000 | n/a |
DL0238 # 05 Y:2024 | 05 | 2024 | RECOVER WASTE HEAT FROM EQUIPMENT | $40,888 | $180,000 | n/a |
DL0238 # 04 Y:2024 | 04 | 2024 | REPAIR OR REPLACE STEAM TRAPS | $112,874 | $37,000 | n/a |
DL0238 # 03 Y:2024 | 03 | 2024 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $205,595 | $34,400 | n/a |
DL0238 # 02 Y:2024 | 02 | 2024 | UPGRADE CONTROLS ON COMPRESSORS | $21,276 | $7,300 | n/a |
DL0238 # 01 Y:2024 | 01 | 2024 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $236,055 | $1,860,000 | n/a |
DL0113 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,030 | $18,354 | Implemented |
DL0113 # 06 Y:2013 | 06 | 2013 | UPGRADE CONTROLS ON COMPRESSORS | $8,270 | $7,000 | Not Implemented |
DL0113 # 01 Y:2013 | 01 | 2013 | RECOVER AND REUSE COOLING WATER | $33,000 | $135,000 | Not Implemented |
DL0113 # 02 Y:2013 | 02 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,884 | $2,770 | Implemented |
DL0113 # 03 Y:2013 | 03 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,300 | $4,043 | Not Implemented |
DL0113 # 04 Y:2013 | 04 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,800 | $7,588 | Implemented |
DL0113 # 05 Y:2013 | 05 | 2013 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $25,100 | $9,800 | Not Implemented |
DL0057 # 02 Y:2010 | 02 | 2010 | CLOSE OFF UNNEEDED STEAM LINES | $8,876 | $415 | Implemented |
DL0057 # 10 Y:2010 | 10 | 2010 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $170,615 | $510,000 | Not Implemented |
DL0057 # 09 Y:2010 | 09 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $88,954 | $200,000 | Not Implemented |
DL0057 # 08 Y:2010 | 08 | 2010 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $430,429 | $460,000 | Not Implemented |
DL0057 # 07 Y:2010 | 07 | 2010 | REDUCE VENTILATION AIR | $28,926 | $30,000 | Implemented |
DL0057 # 06 Y:2010 | 06 | 2010 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $38,896 | $22,745 | Not Implemented |
DL0057 # 05 Y:2010 | 05 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $413,326 | $133,000 | Implemented |
DL0057 # 04 Y:2010 | 04 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,305 | $2,960 | Implemented |
DL0057 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $143,083 | $15,941 | Implemented |
DL0057 # 01 Y:2010 | 01 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $39,401 | $83 | Not Implemented |
WV0278 # 01 Y:2003 | 01 | 2003 | RECOVER AND REUSE WASTE MATERIAL | $81,748 | $300,000 | Not Implemented |