Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,413
matching recommendationsNAICS | 3115 | Dairy Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0377 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $401 | $816 | Implemented |
AS0377 # 06 Y:2004 | 06 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $193 | $344 | Implemented |
AS0377 # 07 Y:2004 | 07 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $331 | $200 | Implemented |
AS0377 # 08 Y:2004 | 08 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $2,085 | $40 | Implemented |
AS0377 # 09 Y:2004 | 09 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $156,863 | $200,000 | Implemented |
MI0074 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,720 | $2,100 | Implemented |
MI0074 # 02 Y:2004 | 02 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,307 | $0 | Not Implemented |
MI0074 # 03 Y:2004 | 03 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $14,422 | $2,605 | Implemented |
MI0074 # 04 Y:2004 | 04 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $680 | $278 | Implemented |
MI0074 # 05 Y:2004 | 05 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,546 | $30,200 | Not Implemented |
MI0074 # 06 Y:2004 | 06 | 2004 | KEEP BOILER TUBES CLEAN | $18,447 | $30,050 | Implemented |
MI0074 # 07 Y:2004 | 07 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,115 | $9,153 | Not Implemented |
SF0275 # 01 Y:2004 | 01 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,063 | $739 | Not Implemented |
SF0275 # 02 Y:2004 | 02 | 2004 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $49,562 | $39,000 | Implemented |
SF0275 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,238 | $0 | Implemented |
SF0275 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,909 | $3,688 | Implemented |
SF0275 # 05 Y:2004 | 05 | 2004 | COVER OPEN TANKS | $715 | $1,469 | Not Implemented |
SF0275 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,604 | $12,835 | Not Implemented |
SF0275 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $1,197 | $4,096 | Not Implemented |
SF0275 # 08 Y:2004 | 08 | 2004 | USE PHOTOCELL CONTROLS | $613 | $2,971 | Not Implemented |
SF0275 # 09 Y:2004 | 09 | 2004 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $30,592 | $34,814 | Not Implemented |
IC0076 # 01 Y:2004 | 01 | 2004 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $39,009 | $67,300 | Not Implemented |
IC0076 # 02 Y:2004 | 02 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,524 | $49,376 | Implemented |
IC0076 # 03 Y:2004 | 03 | 2004 | ISOLATE HOT OR COLD EQUIPMENT | $1,539 | $364 | Not Implemented |
IC0076 # 04 Y:2004 | 04 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $2,133 | $2,700 | Implemented |