Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,165

matching recommendations
Reset
NAICS 31151 Dairy Product (except Frozen) Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0451 # 06 Y:2010 06 2010 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $11,080 $240,000 Not Implemented
UW0035 # 01 Y:2010 01 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $58,000 $0 Not Implemented
UW0035 # 02 Y:2010 02 2010 IMPROVE COMBUSTION CONTROL CAPABILITY $28,000 $77,000 Implemented
UW0035 # 03 Y:2010 03 2010 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $18,058 $1 Implemented
UW0035 # 04 Y:2010 04 2010 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,417 $0 Not Implemented
UW0035 # 05 Y:2010 05 2010 INSULATE BARE EQUIPMENT $3,700 $2,000 Implemented
AM0560 # 01 Y:2009 01 2009 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $117,000 $1,000,000 Not Implemented
AM0560 # 02 Y:2009 02 2009 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $17,860 $25,000 Implemented
AM0560 # 03 Y:2009 03 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $31,130 $70,250 Implemented
AM0560 # 04 Y:2009 04 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $25,120 $2,500 Implemented
AM0560 # 05 Y:2009 05 2009 REPAIR OR REPLACE STEAM TRAPS $16,000 $1,900 Implemented
AM0560 # 06 Y:2009 06 2009 INSULATE BARE EQUIPMENT $10,970 $2,190 Implemented
AM0560 # 07 Y:2009 07 2009 USE SYNTHETIC LUBRICANT $2,715 $0 Implemented
AM0560 # 08 Y:2009 08 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,495 $670 Implemented
AM0560 # 09 Y:2009 09 2009 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $620 $0 Implemented
TT0023 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $21,401 $13,400 Not Implemented
TT0023 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,785 $23,530 Not Implemented
TT0023 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,700 $11,100 Not Implemented
TT0023 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,685 $7,344 Not Implemented
TT0023 # 05 Y:2008 05 2008 REPAIR AND ELIMINATE STEAM LEAKS $55,100 $20,000 Implemented
TT0023 # 06 Y:2008 06 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $37,200 $1,000 Implemented
TT0023 # 07 Y:2008 07 2008 INSTALL / REPAIR INSULATION ON STEAM LINES $13,600 $8,310 Implemented
TT0023 # 08 Y:2008 08 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,275 $4,900 Implemented
TT0023 # 09 Y:2008 09 2008 REPAIR OR REPLACE STEAM TRAPS $1,750 $1,600 Implemented
TT0023 # 10 Y:2008 10 2008 OPTIMIZE PLANT POWER FACTOR $15,500 $32,800 Not Implemented