IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

345

matching recommendations
Reset
NAICS 311513 Cheese Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0289 # 03 Y:2005 03 2005 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,275 $6,900 Implemented
BD0289 # 04 Y:2005 04 2005 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,225 $1,500 Not Implemented
BD0289 # 05 Y:2005 05 2005 INSTALL OCCUPANCY SENSORS $910 $1,050 Implemented
BD0289 # 06 Y:2005 06 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $694 $900 Not Implemented
BD0289 # 07 Y:2005 07 2005 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $770 $1,780 Implemented
BD0289 # 08 Y:2005 08 2005 USE POWER DURING OFF-PEAK PERIODS $484 $0 Implemented
BD0289 # 09 Y:2005 09 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $315 $576 Implemented
BD0289 # 10 Y:2005 10 2005 PAY BILLS ON TIME TO AVOID LATE FEES $1,052 $0 Not Implemented
BD0289 # 11 Y:2005 11 2005 INSTALL AUTOMATIC PACKING EQUIPMENT $57,600 $105,000 Implemented
AS0394 # 01 Y:2005 01 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,769 $3,632 Not Implemented
AS0394 # 02 Y:2005 02 2005 DIRECT WARMEST AIR TO COMBUSTION INTAKE $18,219 $1,000 Not Implemented
AS0394 # 03 Y:2005 03 2005 INSTALL / REPAIR INSULATION ON STEAM LINES $1,961 $321 Not Implemented
AS0394 # 04 Y:2005 04 2005 USE HEAT EXCHANGE FLUIDS INSTEAD OF STEAM IN PIPELINE TRACING SYSTEMS $71,792 $33,000 Not Implemented
AS0394 # 05 Y:2005 05 2005 INSTALL AUTOMATIC PACKING EQUIPMENT $443,040 $453,047 Implemented
UU0081 # 01 Y:2005 01 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,948 $2,000 Not Implemented
UU0081 # 02 Y:2005 02 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,684 $6,171 Not Implemented
UU0081 # 03 Y:2005 03 2005 INSTALL COMMON HEADER ON COMPRESSORS $1,717 $1,270 Not Implemented
UU0081 # 04 Y:2005 04 2005 INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM $2,724 $11,700 Not Implemented
UU0081 # 05 Y:2005 05 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,000 $500 Not Implemented
UU0081 # 06 Y:2005 06 2005 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $996,810 $10,000,000 Not Implemented
UU0081 # 07 Y:2005 07 2005 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $117 $0 Not Implemented
UD0701 # 01 Y:2004 01 2004 REDUCE OR ELIMINATE WASTE $85,956 $19,600 Not Implemented
UD0701 # 02 Y:2004 02 2004 REDUCE EXCESSIVE BOILER BLOWDOWN $55,242 $1,619 Not Implemented
UD0701 # 03 Y:2004 03 2004 METER WASTE WATER $51,851 $15,700 Not Implemented
UD0701 # 04 Y:2004 04 2004 REDUCE OR ELIMINATE WASTE $38,220 $620 Not Implemented