Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
69
matching recommendationsNAICS | 31161 | Animal Slaughtering and Processing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0255 # 04 Y:2006 | 04 | 2006 | REPAIR AND ELIMINATE STEAM LEAKS | $16,453 | $19,600 | Not Implemented |
LL0255 # 03 Y:2006 | 03 | 2006 | INSULATE BARE EQUIPMENT | $32,476 | $8,296 | Not Implemented |
LL0255 # 02 Y:2006 | 02 | 2006 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $72,962 | $24,500 | Not Implemented |
LL0255 # 01 Y:2006 | 01 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $76,757 | $77,280 | Not Implemented |
LL0255 # 10 Y:2006 | 10 | 2006 | USE PHOTOCELL CONTROLS | $244 | $30 | Implemented |
LL0236 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $295 | $100 | Implemented |
LL0236 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,322 | $4,300 | Implemented |
LL0236 # 02 Y:2005 | 02 | 2005 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $5,274 | $9,000 | Implemented |
LL0236 # 03 Y:2005 | 03 | 2005 | INSULATE BARE EQUIPMENT | $3,312 | $500 | Implemented |
LL0236 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $772 | $0 | Not Implemented |
LL0236 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $688 | $300 | Implemented |
LL0236 # 07 Y:2005 | 07 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $25,780 | $0 | Not Implemented |
LL0231 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $25,544 | $0 | Not Implemented |
LL0231 # 07 Y:2005 | 07 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $390 | $0 | Not Implemented |
LL0231 # 06 Y:2005 | 06 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $108,500 | $0 | Not Implemented |
LL0231 # 05 Y:2005 | 05 | 2005 | USE PHOTOCELL CONTROLS | $165 | $0 | Not Implemented |
LL0231 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,367 | $0 | Not Implemented |
LL0231 # 03 Y:2005 | 03 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,216 | $750 | Implemented |
LL0231 # 02 Y:2005 | 02 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $10,617 | $500 | Implemented |