Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
478
matching recommendationsNAICS | 311612 | Meat Processed from Carcasses |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0507 # 06 Y:2006 | 06 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,000 | $500 | Implemented |
AM0507 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,240 | $400 | Implemented |
AM0507 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,900 | $9,900 | Implemented |
AM0507 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,430 | $1,620 | Implemented |
AM0507 # 10 Y:2006 | 10 | 2006 | USE SYNTHETIC LUBRICANT | $733 | $0 | Implemented |
AM0507 # 11 Y:2006 | 11 | 2006 | USE PHOTOCELL CONTROLS | $1,120 | $100 | Implemented |
AM0507 # 12 Y:2006 | 12 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $938 | $215 | Implemented |
IA0380 # 01 Y:2006 | 01 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $336 | $25 | Implemented |
IA0380 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $685 | $215 | Implemented |
IA0380 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $262 | $879 | Implemented |
IA0380 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,513 | $8,142 | Not Implemented |
IA0380 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,037 | $1,906 | Not Implemented |
IA0380 # 06 Y:2006 | 06 | 2006 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $11,632 | $4,000 | Not Implemented |
IA0380 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $298 | $650 | Not Implemented |
IA0380 # 08 Y:2006 | 08 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $35,020 | $29,000 | Not Implemented |
UU0093 # 01 Y:2005 | 01 | 2005 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $336,460 | $336,000 | Not Implemented |
UU0093 # 02 Y:2005 | 02 | 2005 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $727 | $495 | Not Implemented |
UU0093 # 03 Y:2005 | 03 | 2005 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $350 | $2,000 | Not Implemented |
UU0093 # 04 Y:2005 | 04 | 2005 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $19,080 | $0 | Not Implemented |
UU0093 # 05 Y:2005 | 05 | 2005 | PAY UTILITY BILLS ON TIME | $1,418 | $0 | Not Implemented |
UU0093 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $777 | $2,000 | Not Implemented |
CO0556 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,670 | $340 | Implemented |
CO0556 # 02 Y:2004 | 02 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $765 | $926 | Implemented |
CO0556 # 03 Y:2004 | 03 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $460 | $780 | Implemented |
CO0556 # 04 Y:2004 | 04 | 2004 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $13,870 | $50,000 | Not Implemented |