Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
288
matching recommendationsNAICS | 3117 | Seafood Product Preparation and Packaging |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0132 # 02 Y:2019 | 02 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,306 | $8,640 | Not Implemented |
WM0132 # 01 Y:2019 | 01 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $21,662 | $106,000 | Not Implemented |
TR0004 # 08 Y:2017 | 08 | 2017 | USE OTHER METHODS FOR NEUTRALIZATION | $258,000 | $292,000 | Not Implemented |
TR0004 # 07 Y:2017 | 07 | 2017 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $27,235 | $100,864 | Not Implemented |
TR0004 # 06 Y:2017 | 06 | 2017 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,148 | $29,271 | Not Implemented |
TR0004 # 05 Y:2017 | 05 | 2017 | OPTIMIZE PLANT POWER FACTOR | $12,722 | $56,000 | Implemented |
TR0004 # 04 Y:2017 | 04 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $273 | $0 | Implemented |
TR0004 # 03 Y:2017 | 03 | 2017 | INSTALL REPLACEMENT DOORS | $2,305 | $10,000 | Implemented |
TR0004 # 02 Y:2017 | 02 | 2017 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,912 | $0 | Implemented |
TR0004 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $666 | $1,325 | Implemented |
GT0899 # 01 Y:2017 | 01 | 2017 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $108,707 | $1,008 | Not Implemented |
GT0899 # 02 Y:2017 | 02 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $7,187 | $1,000 | Implemented |
GT0899 # 03 Y:2017 | 03 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $29,097 | $4,967 | Implemented |
GT0899 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $40,882 | $10,400 | Not Implemented |
GT0899 # 05 Y:2017 | 05 | 2017 | INSTALL OCCUPANCY SENSORS | $8,883 | $9,708 | Implemented |
GT0899 # 06 Y:2017 | 06 | 2017 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $205,713 | $445,437 | Not Implemented |
MA0761 # 04 Y:2016 | 04 | 2016 | MINIMIZE WATER USAGE | $3,035 | $4,050 | Not Implemented |
MA0761 # 06 Y:2016 | 06 | 2016 | OPTIMIZE PLANT POWER FACTOR | $816 | $2,000 | Not Implemented |
MA0761 # 05 Y:2016 | 05 | 2016 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $864 | $342 | Not Implemented |
MA0761 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,969 | $6,409 | Not Implemented |
MA0761 # 02 Y:2016 | 02 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,889 | $2,685 | Not Implemented |
MA0761 # 01 Y:2016 | 01 | 2016 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $22,997 | $134,000 | Not Implemented |
OR0661 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,783 | $2,340 | Not Implemented |
OR0661 # 01 Y:2015 | 01 | 2015 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $52,251 | $18,807 | Implemented |
OR0661 # 02 Y:2015 | 02 | 2015 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $76,637 | $205,256 | Not Implemented |