IAC logo
IAC Assessment: TR0004
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: TR0004
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Texas Rio Grande Valley
Assessment Year 2017
Principal Product Frozen seafood products and frozen appetizers
NAICS 311710 - Seafood Product Preparation and Packaging
SIC 2092 - Fresh Or Frozen Prepared Fish
Sales $100,000,000-$500,000,000
# of Employees 300
Plant Area (Sq.Ft.) 124,000
Annual Production 35,000,000 Pounds
Production Hrs. Annual 7,848
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $825,580 15,285,600 kWh $0.05
Electricity Demand $254,159 32,226 kW-months/year $7.89
Electricity Fees $9,211 - $ -
TOTAL ENERGY COSTS $1,285,470
RECOMMENDED SAVINGS* $314,261 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $20,878
#|Description Savings
Cost
Status Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$666
Cost:
$1,325
$666 12,230 - - - - $666
12,230
kWh
-
-
kW-months/year
-
-
$
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$4,912
Cost:
-
- - $4,912 628 - - -
-
kWh
$4,912
628
kW-months/year
-
-
$
03: 2.7495 INSTALL REPLACEMENT DOORS Savings:
$2,305
Cost:
$10,000
$2,305 42,319 - - - - $2,305
42,319
kWh
-
-
kW-months/year
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$273
Cost:
-
$171 3,140 $102 13 - - $171
3,140
kWh
$102
13
kW-months/year
-
-
$
05: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$12,722
Cost:
$56,000
- - $12,722 1,620 - - -
-
kWh
$12,722
1,620
kW-months/year
-
-
$
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$8,148
Cost:
$29,271
$6,674 122,540 $1,474 192 - - $6,674
122,540
kWh
$1,474
192
kW-months/year
-
-
$
07: 3.3128 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS Savings:
$27,235
Cost:
$100,864
- - - - $27,235 - -
-
kWh
-
-
kW-months/year
$27,235
-
$
08: 3.3113 USE OTHER METHODS FOR NEUTRALIZATION Savings:
$258,000
Cost:
$292,000
- - - - $258,000 - -
-
kWh
-
-
kW-months/year
$258,000
-
$
TOTAL RECOMMENDED Savings:
$314,261
Cost:
$489,460
$9,816 180,229 $19,210 2,453 $285,235 - $9,816
180,229
kWh
$19,210
2,453
kW-months/year
$285,235
-
$
TOTAL IMPLEMENTED Savings:
$20,878
Cost:
$67,325
$3,142 57,689 $17,736 2,261 - - $3,142
57,689
kWh
$17,736
2,261
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost