Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Texas Rio Grande Valley |
---|---|
Assessment Year | 2017 |
Principal Product | Frozen seafood products and frozen appetizers |
NAICS | 311710 - Seafood Product Preparation and Packaging |
SIC | 2092 - Fresh Or Frozen Prepared Fish |
Sales | $100,000,000-$500,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 124,000 |
Annual Production | 35,000,000 Pounds |
Production Hrs. Annual | 7,848 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $825,580 | 15,285,600 | kWh | $0.05 |
Electricity Demand | $254,159 | 32,226 | kW-months/year | $7.89 |
Electricity Fees | $9,211 | - | $ | - |
TOTAL ENERGY COSTS | $1,285,470 | |||
RECOMMENDED SAVINGS* | $314,261 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,878 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $666 Cost: $1,325 |
$666 | 12,230 | - | - | - | - |
$666 12,230 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $4,912 Cost: - |
- | - | $4,912 | 628 | - | - |
- - kWh |
$4,912 628 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7495 INSTALL REPLACEMENT DOORS |
Savings: $2,305 Cost: $10,000 |
$2,305 | 42,319 | - | - | - | - |
$2,305 42,319 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $273 Cost: - |
$171 | 3,140 | $102 | 13 | - | - |
$171 3,140 kWh |
$102 13 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $12,722 Cost: $56,000 |
- | - | $12,722 | 1,620 | - | - |
- - kWh |
$12,722 1,620 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $8,148 Cost: $29,271 |
$6,674 | 122,540 | $1,474 | 192 | - | - |
$6,674 122,540 kWh |
$1,474 192 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.3128 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS |
Savings: $27,235 Cost: $100,864 |
- | - | - | - | $27,235 | - |
- - kWh |
- - kW-months/year |
$27,235 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.3113 USE OTHER METHODS FOR NEUTRALIZATION |
Savings: $258,000 Cost: $292,000 |
- | - | - | - | $258,000 | - |
- - kWh |
- - kW-months/year |
$258,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $314,261 Cost: $489,460 |
$9,816 | 180,229 | $19,210 | 2,453 | $285,235 | - | $9,816 180,229 kWh |
$19,210 2,453 kW-months/year |
$285,235 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,878 Cost: $67,325 |
$3,142 | 57,689 | $17,736 | 2,261 | - | - | $3,142 57,689 kWh |
$17,736 2,261 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost |