Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,542
matching recommendationsNAICS | 3118 | Bakeries and Tortilla Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0388 # 05 Y:2006 | 05 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,306 | $0 | Implemented |
SD0388 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $3,744 | $1,280 | Not Implemented |
IC0121 # 01 Y:2006 | 01 | 2006 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,152 | $4,984 | Implemented |
IC0121 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,664 | $700 | Implemented |
IC0121 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,928 | $9,302 | Not Implemented |
IC0121 # 04 Y:2006 | 04 | 2006 | INSTALL TURBULATORS | $7,715 | $23,253 | Not Implemented |
IC0121 # 05 Y:2006 | 05 | 2006 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $20,185 | $115,000 | Not Implemented |
IC0121 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $440 | $1,664 | Implemented |
IC0121 # 07 Y:2006 | 07 | 2006 | INCREASE AMOUNT OF CONDENSATE RETURNED | $18,627 | $88,113 | Not Implemented |
IC0121 # 08 Y:2006 | 08 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,394 | $27,491 | Implemented |
IC0121 # 09 Y:2006 | 09 | 2006 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $7,933 | $89,400 | Not Implemented |
UM0312 # 01 Y:2006 | 01 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,410 | $500 | Not Implemented |
UM0312 # 02 Y:2006 | 02 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $14,289 | $4,200 | Not Implemented |
UM0312 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,355 | $15,984 | Not Implemented |
UM0312 # 04 Y:2006 | 04 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,421 | $100 | Not Implemented |
UM0312 # 05 Y:2006 | 05 | 2006 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,885 | $2,250 | Implemented |
UM0312 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,862 | $200 | Not Implemented |
UM0312 # 07 Y:2006 | 07 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,826 | $1,300 | Not Implemented |
UM0312 # 08 Y:2006 | 08 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,622 | $800 | Not Implemented |
UM0312 # 09 Y:2006 | 09 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $857 | $300 | Not Implemented |
UM0312 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $508 | $276 | Not Implemented |
SF0334 # 01 Y:2006 | 01 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,513 | $460 | Not Implemented |
SF0334 # 02 Y:2006 | 02 | 2006 | HEAT WATER WITH EXHAUST HEAT | $27,840 | $27,600 | Not Implemented |
SF0334 # 03 Y:2006 | 03 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,063 | $5,347 | Not Implemented |
SF0334 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $455 | $638 | Not Implemented |