Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

62

matching recommendations
Reset
NAICS 3118 Bakeries and Tortilla Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0857 # 07 Y:2008 07 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,400 $30,135 Not Implemented
GT0857 # 02 Y:2008 02 2008 RECOVER WASTE HEAT FROM EQUIPMENT $142,150 $130,500 Not Implemented
GT0857 # 01 Y:2008 01 2008 REPAIR OR REPLACE STEAM TRAPS $21,870 $12,000 Not Implemented
GT0857 # 03 Y:2008 03 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,834 $29,404 Not Implemented
GT0857 # 04 Y:2008 04 2008 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,781 $20,000 Not Implemented
GT0857 # 05 Y:2008 05 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $42,655 $119,957 Not Implemented
GT0857 # 06 Y:2008 06 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,243 $1,636 Not Implemented
AM0551 # 01 Y:2008 01 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $42,500 $1,550 Implemented
AM0551 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,950 $32,300 Implemented
AM0551 # 03 Y:2008 03 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $13,330 $12,480 Implemented
AM0551 # 04 Y:2008 04 2008 CHECK FOR ACCURACY OF UTILITY / POWER METERS $6,600 $5,000 Implemented
AM0551 # 05 Y:2008 05 2008 IMPROVE HANDLING PRACTICES $5,090 $110 Implemented
AM0551 # 06 Y:2008 06 2008 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,800 $1,000 Implemented
AM0551 # 07 Y:2008 07 2008 USE SYNTHETIC LUBRICANT $2,200 $0 Not Implemented
AM0551 # 08 Y:2008 08 2008 INSULATE BARE EQUIPMENT $580 $90 Not Implemented
AM0551 # 09 Y:2008 09 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $490 $380 Implemented
UW0021 # 02 Y:2008 02 2008 OPERATE BOILERS ON HIGH FIRE SETTING $20,223 $49,000 Not Implemented
UW0021 # 06 Y:2008 06 2008 INSTALL OCCUPANCY SENSORS $478 $450 Not Implemented
UW0021 # 05 Y:2008 05 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,472 $0 Not Implemented
UW0021 # 04 Y:2008 04 2008 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $5,612 $50,000 Not Implemented
UW0021 # 03 Y:2008 03 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,357 $5,912 Not Implemented
UW0021 # 01 Y:2008 01 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $52,486 $175,000 Not Implemented
MS0330 # 01 Y:2008 01 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $21,490 $1,800 Implemented
MS0330 # 02 Y:2008 02 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,879 $1,000 Implemented
MS0330 # 03 Y:2008 03 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $12,253 $401 Implemented