Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,192
matching recommendationsNAICS | 31181 | Bread and Bakery Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0903 # 12 Y:2014 | 12 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,173 | $3,510 | Implemented |
UD0903 # 13 Y:2014 | 13 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $960 | $1,990 | Implemented |
MA0716 # 01 Y:2013 | 01 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $33,408 | $70,705 | Implemented |
MA0716 # 02 Y:2013 | 02 | 2013 | ADOPT IN-HOUSE MATERIAL GENERATION | $20,977 | $22,000 | Implemented |
MA0716 # 03 Y:2013 | 03 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $18,072 | $35,000 | Implemented |
MA0716 # 04 Y:2013 | 04 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,554 | $10,000 | Implemented |
MA0716 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,726 | $10,000 | Implemented |
MA0716 # 06 Y:2013 | 06 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,965 | $6,300 | Implemented |
MA0716 # 07 Y:2013 | 07 | 2013 | INSULATE BARE EQUIPMENT | $1,343 | $935 | Implemented |
MA0716 # 08 Y:2013 | 08 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,141 | $4,000 | Implemented |
MA0716 # 09 Y:2013 | 09 | 2013 | INSTALL OCCUPANCY SENSORS | $322 | $400 | Implemented |
OR0613 # 01 Y:2013 | 01 | 2013 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $11,140 | $5,000 | Implemented |
OR0613 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $3,040 | $2,913 | Not Implemented |
OR0613 # 03 Y:2013 | 03 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,262 | $36,000 | Implemented |
OR0613 # 04 Y:2013 | 04 | 2013 | RECOVER AND REUSE WASTE MATERIAL | $3,635 | $8,000 | Not Implemented |
OR0613 # 05 Y:2013 | 05 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,364 | $17,632 | Not Implemented |
OR0613 # 06 Y:2013 | 06 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $991 | $95 | Implemented |
OR0613 # 07 Y:2013 | 07 | 2013 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $706 | $448 | Implemented |
OK0866 # 01 Y:2013 | 01 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,260 | $28,000 | Not Implemented |
OK0866 # 03 Y:2013 | 03 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $19,312 | $184,080 | Not Implemented |
OK0866 # 13 Y:2013 | 13 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $189 | $2,098 | Not Implemented |
OK0866 # 02 Y:2013 | 02 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $14,259 | $28,400 | Not Implemented |
OK0866 # 04 Y:2013 | 04 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $4,776 | $1,440 | Implemented |
OK0866 # 05 Y:2013 | 05 | 2013 | INSTALL SET-BACK TIMERS | $449 | $318 | Implemented |
OK0866 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $865 | $3,992 | Not Implemented |