Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsNAICS | 31181 | Bread and Bakery Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0474 # 08 Y:2019 | 08 | 2019 | USE SOLAR HEAT TO MAKE ELECTRICTY | $41,537 | $280,000 | Not Implemented |
LE0474 # 07 Y:2019 | 07 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $150,418 | $721,000 | Not Implemented |
LE0474 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,789 | $6,400 | Not Implemented |
LE0474 # 05 Y:2019 | 05 | 2019 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $73,547 | $220,000 | Not Implemented |
LE0474 # 04 Y:2019 | 04 | 2019 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $17,687 | $22,000 | Not Implemented |
LE0474 # 03 Y:2019 | 03 | 2019 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $28,595 | $35,000 | Not Implemented |
LE0474 # 02 Y:2019 | 02 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,754 | $20,000 | Not Implemented |
LE0474 # 01 Y:2019 | 01 | 2019 | INSTALL TIMERS AND/OR THERMOSTATS | $6,222 | $0 | Not Implemented |
LE0394 # 07 Y:2015 | 07 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $734 | $1,500 | Not Implemented |
LE0394 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $415 | $1,615 | Not Implemented |
LE0394 # 10 Y:2015 | 10 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $207 | $550 | Not Implemented |
LE0394 # 09 Y:2015 | 09 | 2015 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,298 | $20,000 | Not Implemented |
LE0394 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,987 | $4,340 | Not Implemented |
LE0394 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,528 | $5,688 | Not Implemented |
LE0394 # 05 Y:2015 | 05 | 2015 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $11,973 | $5,000 | Not Implemented |
LE0394 # 04 Y:2015 | 04 | 2015 | INSTALL / REPAIR INSULATION ON STEAM LINES | $914 | $200 | Not Implemented |
LE0394 # 03 Y:2015 | 03 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,611 | $25 | Not Implemented |
LE0394 # 02 Y:2015 | 02 | 2015 | REPLACE BOILER | $16,261 | $75 | Not Implemented |
LE0394 # 01 Y:2015 | 01 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $65,897 | $0 | Not Implemented |
DL0140 # 01 Y:2015 | 01 | 2015 | REDUCE VENTILATION AIR | $169,710 | $0 | Implemented |
DL0140 # 06 Y:2015 | 06 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $25,660 | $74,190 | Not Implemented |
DL0140 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $3,810 | $1,640 | Not Implemented |
DL0140 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $60,305 | $98,895 | Not Implemented |
DL0140 # 03 Y:2015 | 03 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $5,235 | $3,000 | Implemented |
DL0140 # 02 Y:2015 | 02 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,140 | $5,060 | Not Implemented |