Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

31

matching recommendations
Reset
NAICS 311813 Frozen Cakes, Pies, and Other Pastries Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0988 # 04 Y:2018 04 2018 USE SOLAR HEAT TO HEAT WATER $4,920 $155,149 Not Implemented
OK0988 # 02 Y:2018 02 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $739 $2,330 Not Implemented
OK0988 # 01 Y:2018 01 2018 OPTIMIZE PLANT POWER FACTOR $7,394 $12,000 Not Implemented
OK0988 # 03 Y:2018 03 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,279 $15,642 Not Implemented
OK0866 # 01 Y:2013 01 2013 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $18,260 $28,000 Not Implemented
OK0866 # 13 Y:2013 13 2013 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $189 $2,098 Not Implemented
OK0866 # 12 Y:2013 12 2013 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $2,408 $2,686 Not Implemented
OK0866 # 11 Y:2013 11 2013 INSULATE BARE EQUIPMENT $232 $280 Implemented
OK0866 # 10 Y:2013 10 2013 INCREASE AMOUNT OF CONDENSATE RETURNED $1,019 $700 Not Implemented
OK0866 # 09 Y:2013 09 2013 RECOVER WASTE HEAT FROM EQUIPMENT $5,915 $2,598 Not Implemented
OK0866 # 08 Y:2013 08 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $299 $463 Not Implemented
OK0866 # 07 Y:2013 07 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,853 $22,216 Not Implemented
OK0866 # 06 Y:2013 06 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $865 $3,992 Not Implemented
OK0866 # 05 Y:2013 05 2013 INSTALL SET-BACK TIMERS $449 $318 Implemented
OK0866 # 04 Y:2013 04 2013 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $4,776 $1,440 Implemented
OK0866 # 03 Y:2013 03 2013 UTILIZE A LESS EXPENSIVE COOLING METHOD $19,312 $184,080 Not Implemented
OK0866 # 02 Y:2013 02 2013 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $14,259 $28,400 Not Implemented
OK0866 # 14 Y:2013 14 2013 REDUCE HEAT GAIN BY WINDOW TINTING $1,077 $16,000 Implemented
OK0700 # 12 Y:2005 12 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $317 $156 Not Implemented
OK0700 # 11 Y:2005 11 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,733 $1,499 Not Implemented
OK0700 # 09 Y:2005 09 2005 INSULATE BARE EQUIPMENT $942 $2,046 Not Implemented
OK0700 # 08 Y:2005 08 2005 INSULATE BARE EQUIPMENT $5,958 $2,709 Not Implemented
OK0700 # 06 Y:2005 06 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $9,498 $21,600 Not Implemented
OK0700 # 05 Y:2005 05 2005 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $29,149 $3,000 Not Implemented
OK0700 # 03 Y:2005 03 2005 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $6,054 $6,238 Not Implemented