Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,762
matching recommendationsNAICS | 3119 | Other Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0168 # 15 Y:2010 | 15 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $445 | $0 | Implemented |
BD0366 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $9,620 | $210 | Implemented |
BD0366 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,837 | $2,700 | Implemented |
BD0366 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,342 | $1,000 | Not Implemented |
BD0366 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,922 | $0 | Not Implemented |
BD0366 # 05 Y:2010 | 05 | 2010 | IMPROVE LUBRICATION PRACTICES | $2,368 | $600 | Implemented |
BD0366 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,606 | $3,000 | Not Implemented |
BD0366 # 07 Y:2010 | 07 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $21,299 | $18,000 | n/a |
BD0366 # 08 Y:2010 | 08 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,581 | $6,400 | Implemented |
BD0366 # 09 Y:2010 | 09 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $565 | $0 | Not Implemented |
LL0323 # 01 Y:2009 | 01 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $116,211 | $8,680 | Implemented |
LL0323 # 02 Y:2009 | 02 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $8,990 | $990 | Not Implemented |
LL0323 # 03 Y:2009 | 03 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,498 | $990 | Not Implemented |
LL0323 # 04 Y:2009 | 04 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $682 | $623 | Not Implemented |
LL0323 # 05 Y:2009 | 05 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $315 | $190 | Not Implemented |
OK0783 # 01 Y:2009 | 01 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $29,321 | $280,000 | Not Implemented |
OK0783 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $112 | $887 | Implemented |
OK0783 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,151 | $775 | Implemented |
OK0783 # 04 Y:2009 | 04 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,327 | $26,066 | Not Implemented |
OK0783 # 05 Y:2009 | 05 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,219 | $15,039 | Not Implemented |
OK0783 # 06 Y:2009 | 06 | 2009 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,392 | $67,320 | Not Implemented |
OK0783 # 07 Y:2009 | 07 | 2009 | ADJUST BURNERS FOR EFFICIENT OPERATION | $18,978 | $3,810 | Implemented |
OK0783 # 08 Y:2009 | 08 | 2009 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $50,901 | $15,708 | Implemented |
OK0783 # 09 Y:2009 | 09 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,399 | $0 | Implemented |
AM0565 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,800 | $14,966 | Implemented |