Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,762
matching recommendationsNAICS | 3119 | Other Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0575 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $68,834 | $23,508 | Implemented |
MA0575 # 02 Y:2005 | 02 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $26,800 | $41,620 | Implemented |
MA0575 # 03 Y:2005 | 03 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $18,805 | $517 | Implemented |
MA0575 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $1,944 | $7,285 | Implemented |
MA0575 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,023 | $0 | Not Implemented |
MA0575 # 06 Y:2005 | 06 | 2005 | OPTIMIZE PLANT POWER FACTOR | $512 | $195 | Not Implemented |
MA0575 # 07 Y:2005 | 07 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $233 | $30 | Not Implemented |
OR0481 # 01 Y:2005 | 01 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $32,471 | $0 | Not Implemented |
OR0481 # 02 Y:2005 | 02 | 2005 | INSTALL SET-BACK TIMERS | $2,880 | $300 | Not Implemented |
OR0481 # 03 Y:2005 | 03 | 2005 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $25,000 | $26,000 | Implemented |
OR0481 # 04 Y:2005 | 04 | 2005 | OPTIMIZE PLANT POWER FACTOR | $7,319 | $8,000 | Not Implemented |
OK0706 # 01 Y:2005 | 01 | 2005 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $10,579 | $1,500 | Implemented |
OK0706 # 02 Y:2005 | 02 | 2005 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $6,672 | $13,451 | Implemented |
OK0706 # 03 Y:2005 | 03 | 2005 | INSTALL SET-BACK TIMERS | $4,084 | $1,468 | Not Implemented |
OK0706 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,296 | $2,239 | Not Implemented |
OK0706 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,610 | $10,437 | Not Implemented |
OK0706 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $1,308 | $802 | Not Implemented |
OK0706 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $821 | $605 | Not Implemented |
CO0562 # 01 Y:2005 | 01 | 2005 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $15,350 | $10,080 | Not Implemented |
CO0562 # 02 Y:2005 | 02 | 2005 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $10,710 | $1,080 | Not Implemented |
CO0562 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,500 | $240 | Implemented |
CO0562 # 04 Y:2005 | 04 | 2005 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $150 | $120 | Implemented |
CO0562 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,290 | $13,190 | Not Implemented |
CO0562 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,530 | $2,350 | Implemented |
CO0562 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,120 | $430 | Implemented |