Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
332
matching recommendationsNAICS | 31194 | Seasoning and Dressing Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0598 # 05 Y:2017 | 05 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $932 | $100 | Implemented |
NC0598 # 04 Y:2017 | 04 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,276 | $1,050 | Not Implemented |
NC0598 # 03 Y:2017 | 03 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,199 | $50 | Not Implemented |
TT0190 # 05 Y:2017 | 05 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $280 | $1,000 | Not Implemented |
TT0190 # 04 Y:2017 | 04 | 2017 | OPTIMIZE PLANT POWER FACTOR | $3,337 | $8,000 | Not Implemented |
TT0190 # 03 Y:2017 | 03 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,110 | $15,000 | Not Implemented |
TT0190 # 02 Y:2017 | 02 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $29,422 | $57,000 | Not Implemented |
TT0190 # 01 Y:2017 | 01 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $53,543 | $127,654 | Not Implemented |
TT0190 # 06 Y:2017 | 06 | 2017 | INSULATE BARE EQUIPMENT | $88 | $200 | Implemented |
NC0586 # 02 Y:2017 | 02 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $308 | $200 | Implemented |
NC0586 # 07 Y:2017 | 07 | 2017 | DEVELOP A REPAIR/REPLACE POLICY | $2,834 | $4,685 | Implemented |
NC0586 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,008 | $2,890 | Implemented |
NC0586 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $929,030 | $400,000 | Implemented |
NC0586 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,873 | $9,000 | Implemented |
NC0586 # 03 Y:2017 | 03 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $988 | $2,500 | Implemented |
NC0586 # 01 Y:2017 | 01 | 2017 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,081 | $2,500 | Implemented |
UD0952 # 08 Y:2016 | 08 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $1,652 | $800 | Implemented |
UD0952 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,764 | $1,000 | Implemented |
UD0952 # 06 Y:2016 | 06 | 2016 | INSTALL TURBULATORS | $6,373 | $3,750 | Not Implemented |
UD0952 # 05 Y:2016 | 05 | 2016 | INSULATE FEEDWATER TANK | $983 | $509 | Not Implemented |
UD0952 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,157 | $0 | Not Implemented |
UD0952 # 03 Y:2016 | 03 | 2016 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,277 | $0 | Not Implemented |
UD0952 # 02 Y:2016 | 02 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,722 | $0 | Implemented |
UD0952 # 01 Y:2016 | 01 | 2016 | COMBINE UTILITY METERS | $26,792 | $0 | Implemented |
UD0952 # 09 Y:2016 | 09 | 2016 | INSTALL OCCUPANCY SENSORS | $10,838 | $19,760 | Not Implemented |